Influence of a municipal solid waste incinerator on ambient air and soil PCDD/Fs levels.
نویسندگان
چکیده
To examine the influence of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) emissions from a municipal solid waste incinerator (MSWI) on the environment, we measured the levels of PCDD/Fs in ambient air and soil samples collected near a MSWI in Bucheon, Korea. The PCDD/Fs concentrations in the ambient air samples ranged from 0.22 to 1.16 pg I-TEQm(-3) (13.39-75.16 pg m(-3)), with an average of 0.66 pg I-TEQ m(-3) (35.62 pg m(-3)). The soil samples contained between 1.25 and 74.98 pg I-TEQ g(-1) (38.15-3,303.33 pg g(-1)), with an average of 19.06 pg I-TEQ g(-1) (1,077.11 pg g(-1)). These levels were higher than those previously reported by other investigators in a number of surveys. The furan homologues predominated in the air samples and some soil samples, and the soil PCDD/Fs levels decreased with increasing distance from the MSWI. Comparison of the homologue patterns and a multivariate statistical analysis showed that PCDD/Fs emission from the MSWI directly affected the pattern of PCDD/Fs in air, while the PCDD/Fs patterns in soil differed according to the location relative to the MSWI, roads, and construction sites. These results collectively indicate that the MSWI was the major PCDD/Fs emission source in this area, but that unidentified combustion sources and vehicles might influence the environment to some extent.
منابع مشابه
Temporal trends in the levels of metals, PCDD/Fs and PCBs in the vicinity of a municipal solid waste incinerator. Preliminary assessment of human health risks.
The concentrations of PCDD/Fs, PCBs, and metals were determined in soil and air samples collected near a municipal solid waste incinerator (MSWI) located in Mataró (Catalonia, Spain), being the health risks for the population living in the vicinity of the facility subsequently assessed. We also established the temporal trends with respect to previous surveys performed in the same zone. In gener...
متن کاملPCDD/F levels in the neighbourhood of a municipal solid waste incinerator after introduction of technical improvements in the facility.
In 1998 and 1999, the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined in soil and herbage samples collected in the vicinity of an old municipal solid waste incinerator (MSWI) (S. Adrià del Besòs, Barcelona, Spain). Just after the 1999 collection, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in this faci...
متن کاملLong-term study of environmental levels of dioxins and furans in the vicinity of a municipal solid waste incinerator.
From 1975 to 2004, a municipal solid waste incinerator (MSWI) was operating in Montcada (Barcelona, Catalonia, Spain). Because of the potential health risks derived from emission of pollutants by the facility, especially polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs), a long-term monitoring program focused on measuring the environmental levels of PCDD/Fs near the facility, ...
متن کاملSpatial distribution of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans in soil around a municipal solid waste incinerator.
Municipal solid waste incinerators (MSWIs) are usually considered to be important sources of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs). To examine the influence of PCDD/Fs emissions from a MSWI on the surrounding environment, 21 soil samples were collected from various sampling sites distributed at distances of 300-1,700 m away from the stack of a MSWI. Inter...
متن کاملEmissions of Polychlorinated Dibenzo-p-dioxins and Dibenzofurans from Various Stationary Sources
This work investigated the characteristics of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) in stack-flue gases from six stationary emission sources in five types of incinerators: industrial waste incinerator (IWI), small-scale municipal solid waste incinerator (MSWI), medical waste incinerator (MWI), cement kilns (CK), and crematories (CR). These characteristics were further inv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chemosphere
دوره 64 4 شماره
صفحات -
تاریخ انتشار 2006