چکیده

OBJECTIVE To examine a contrast medium method using a glucocorticoid-air-saline mixture and ultrasound imaging (GAS-graphy) for the verification of palpation-guided injections in different joints and to assess the inter-reader reliability of the method. METHODS A palpation-guided injection of an air-steroid-saline mixture was given into a joint or tendon sheath of 133 consecutive patients. The dynamic ultrasound monitor images of the joints and tendons involved were videotaped before and after the injection. A rheumatologist and two radiologists analyzed separately the video clips of each patient, under blinded conditions. The readers evaluated the accuracy of the injections and the difficulty of the reading process. The inter-reader agreement was assessed by calculating the percentual values and overall kappa coefficient between the readers. RESULTS The overall accuracy of the successful injections was 76%, 80% and 82 % evaluated by the three readers. In six out of the ten injection sites the accuracy was higher than 80%. The clarity of the method evaluated by the readers was 8, 8 and 8.5 on a scale from 0 to 10. The inter-reader agreement assessed by percentual values was 84.2%, 85.0% and 88.7%. The kappa coefficient between all readers was 0.595 showing moderate agreement. CONCLUSION The GAS-graphy method for the verification of palpation-guided injections is a simple procedure performable to any joint site and the result can be seen immediately on the monitor after the injection. The reliability of the method is good and it can be used in developing injection techniques as well as in medical or nurse education. The method can be used as an alternative for the radiographic contrast medium method in verifying successful palpation-guided intra-articular injections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical utility of ultrasound guidance for intra-articular knee injections: a review

Intra-articular corticosteroid and hyaluronic acid injections provide short-term symptom amelioration for arthritic conditions involving structural damage or degenerative changes in the knee. Conventional palpation-guided anatomical injections frequently result in inaccurate needle placement into extra-articular tissue and adjacent structures. The purpose of this review was to determine the eff...

متن کامل

Ultrasound guidance for intra-articular knee and shoulder injections: a review.

Intra-articular injections have traditionally been performed "blind," guided only by anatomic palpation. Many may be placed inaccurately, and the use of imaging may significantly improve injection accuracy. This review analyzed the impact of ultrasound-guidance on injection accuracy and clinical efficacy in the knee and shoulder joints. Ultrasound-guided injections were significantly more accur...

متن کامل

Palpation Versus Ultrasound-Guided Acromioclavicular Joint Intra-articular Corticosteroid Injections: A Retrospective Comparative Clinical Study.

BACKGROUND Primary osteoarthritis (OA) is the most common cause of pain arising from the acromioclavicular (AC) joint. The true incidence is unknown because of differences in the criteria used to define arthritis in various studies. The proper diagnosis of AC joint OA requires a thorough physical examination, radiographic findings, and a diagnostic local anesthetic injection. OBJECTIVE The go...

متن کامل

Accuracy of Ultrasound-Guided Intra-articular Hip Injections Performed in the Orthopedic Clinic.

Intra-articular hip injections have proven clinical value for both diagnostic and therapeutic purposes. Historically, these injections have been performed by radiologists using fluoroscopic guidance. This necessitates a radiology referral, delays the injection, and represents lost productivity for the orthopedist. Ultrasound-guided intra-articular hip injections have been described in the radio...

متن کامل

Use of air-steroid-saline mixture as contrast medium in greyscale ultrasound imaging: experimental study and practical applications in rheumatology.

OBJECTIVES To investigate experimentally the echogenicity of air, a steroid suspension and physiological saline mixed with water in order to find the best contrast medium for injections. To show the practical applications of an airsteroid-saline mixture as a contrast medium in rheumatology. METHODS In vitro. First, quality assurance measurements were conducted twice on the ultrasound (US) equ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and experimental rheumatology

دوره 24 3  شماره 

صفحات  -

تاریخ انتشار 2006