Noncontact electrical resistivity measurement technique for molten metals

نویسندگان

  • Won-Kyu Rhim
  • Takehiko Ishikawa
چکیده

A noncontact technique of measuring the changes in electrical conductivity ~or resistivity! of conducting liquids is reported. The technique is based on a conducting drop that is levitated by the high-temperature electrostatic levitator in a high vacuum. This technique, which utilizes the principle of the asynchronous induction motor, measures the relative changes in torque as a function of temperature by applying a rotating magnetic field to the sample. Changes in electrical resistivity are related to the changes in measured torque using the formula developed for the induction motor. Validity of this technique was demonstrated using a pure aluminum sample around its melting temperature. When the measurement results were calibrated by a literature value of resistivity at the melting point, our resistivity data around the melting point could be expressed by r liq524.19 11.306310(T2Tm) mV cm over Tm;1160 K, rsolid510.7711.421310 (T2Tm) mV cm over 700 K;Tm , and the thermal conductivity as determined by the Wiedemann–Franz–Lorenz law from the resistivity data was given by k liq(T)594.6114.41310 (T2Tm) W m 21 K, ksolid(T)5211.1327.57310 (T2Tm) W m 21 K. Both electrical resistivity and thermal conductivity are in close agreement with the literature, confirming the validity of the present technique. © 1998 American Institute of Physics. @S0034-6748~98!03510-2#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical Resistivity Measurement of the Molten Cordierite Glass Using Two-wire method

Electrical resistivity (ER) is a main parameter in the melting processes of glasses. However, its measurement is difficult at high temperatures. In this study the electrical resistivity of different cordierite glass samples in the molten state was measured in the temperature range of 1100˚C to 1550 ˚C using the two-wire method. It was attempted to decrease the electrical resistivity of the glas...

متن کامل

Effective Interionic Potentials and Properties of Molten Noble and Transition Metals

Recent X-ray diffraction data on molten noble and transition metals have been used to calculate effective interionic potentials by means of the Born-Green equation. The results on the noble metals are compared with the generalized pseudopotential calculations of Moriarty. In all cases the potentions were found to be insensitive to temperature and to have long-range oscillations. The results sug...

متن کامل

Noncontact electrical characterization of low-resistivity P-type 2nSe:N grown by molecular beam epitaxy

The resistivity of p-type ZnSe:N/GaAs heteroepitaxial layers grown by molecular beam epitaxy using a nitrogen free-radical source has been determined as a funct:ion of both substrate temperature and the Zn-to-Se beam equivalent pressure (BEP) ratio employed during growth, Layer resistivities were determined using a noncontact inductive-coupling radiofrequency measurement technique that provided...

متن کامل

Measurement of the electrical resistivity and Hall coefficient at high temperatures.

The implementation of the van der Pauw (VDP) technique for combined high temperature measurement of the electrical resistivity and Hall coefficient is described. The VDP method is convenient for use since it accepts sample geometries compatible with other measurements. The technique is simple to use and can be used with samples showing a broad range of shapes and physical properties, from near ...

متن کامل

A noncontact measurement technique for the density and thermal expansion coefficient of solid and liquid materials

A noncontact measurement technique for the density and the thermal expansion coefficient of refractory materials in their molten as well as solid phases is presented. This technique is based on the video image processing of a levitated sample. Experiments were performed using the high-temperature electrostatic levitator ~HTESL! at the Jet Propulsion Laboratory in which 2–3 mm diam samples can b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998