Postplacental or delayed insertion of the levonorgestrel intrauterine device after vaginal delivery: a randomized controlled trial.

نویسندگان

  • Beatrice A Chen
  • Matthew F Reeves
  • Jennifer L Hayes
  • Heather L Hohmann
  • Lisa K Perriera
  • Mitchell D Creinin
چکیده

OBJECTIVE To estimate whether 6-month use of the levonorgestrel-releasing intrauterine device (IUD) would be higher when insertion occurred within 10 minutes of placental delivery compared with 6-8 weeks postpartum. METHODS We enrolled pregnant women planning vaginal deliveries and desiring a postpartum levonorgestrel-releasing IUD. Patients were randomly assigned when admitted in labor to postplacental or delayed IUD insertion. The women followed up in person at 6-8 weeks and 6 months and were contacted by telephone at 3 months. Women were ineligible for a study IUD postenrollment for intrapartum events including infection, hemorrhage, and cesarean delivery; these women were contacted by phone at 3 and 6 months. Expelled IUDs were replaced per patient preference. RESULTS Successful IUD placement occurred in 50 of 51 participants (98.0%) and 46 of 51 participants (90.2%) in the postplacental and delayed groups, respectively (P=.2). Expulsion within 6 months occurred in 12 of 50 (24.0%; 95% confidence interval [CI], 13.1-38.2) and two of 46 (4.4%; 95% CI 0.5-14.8) participants, respectively (P=.008). Intrauterine device use at 6 months was 43 of 51 (84.3%; 95% CI 71.4-93.0) and 39 of 51 (76.5%; 95% CI 62.5-87.2), respectively (P=.32). For ineligible patients, only 11 of 41 (26.8%) women were using IUDs at 6 months and two (4.9%) had become pregnant. CONCLUSION Intrauterine device use 6 months after delivery is similar in women who have postpartum or scheduled delayed IUD placement through a study after replacement of expelled IUDs. Expulsions are significantly higher with postplacental compared with delayed IUD placement. Women asked to follow up with their own health care providers for delayed insertion are significantly less likely to receive an IUD. CLINICAL TRIAL REGISTRATION ClinicalTrials.gov, www.clinicaltrials.gov, NCT00476021. LEVEL OF EVIDENCE I.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrauterine device insertion during the postpartum period: a systematic review.

BACKGROUND Insertion of an intrauterine device (IUD) at different times or by different routes during the postpartum period may increase the risk of complications. METHODS We searched Medline, Lilacs and Cochrane Collaboration databases for articles in any language, between database inception until December 2008, which compared outcomes of postpartum IUD insertion time intervals. Search terms...

متن کامل

Immediate postpartum insertion of intrauterine device for contraception.

BACKGROUND Women who want to start intrauterine contraception (IUC) during the postpartum period might benefit from IUC insertion immediately after delivery. Postplacental insertion greatly reduces the risk of subsequent pregnancy and eliminates the need for a return visit to start contraception. Without the option of immediate insertion, many women may never return for services or may adopt le...

متن کامل

Advocating for immediate postpartum LARC: increasing access, improving outcomes, and decreasing cost.

Unintended pregnancy, endemic in the United States Expulsion rates appear to be lower with postplacental (within (US), carries significant health and economic consequences and disproportionately affects poor women and women of color [1,2]. Rapid repeat pregnancy—defined as a pregnancy within 12 to 18 months after delivery—can occur if women are unsuccessful at initiating contraception [3]. Impr...

متن کامل

Immediate postplacental insertion of a copper intrauterine device: a pilot study to evaluate expulsion rate by mode of delivery.

BACKGROUND The present study aimed to investigate risk factors for expulsion in immediate postplacental IUD insertion. We specifically sought to determine whether cesarean delivery before or during labor have an impact on IUD expulsion. METHODS The study included 160 pregnant women for immediate IUD insertion following vaginal or cesarean delivery. Three groups of patients were recruited: Pat...

متن کامل

Effectiveness of Postplacental Intrauterine Contraceptive Device Insertion in Multiparous Women

Aim: To determine effectiveness postplacental intrauterine contraceptive device( PPIUCD) insertion in multiparous women. Design: Descriptive Case Series Place of study: Department of Obstetrics & Gynaecology, Sir Ganga Ram Hospital, Lahore Duration: 6 months Method: 150 multiparous women with normal vaginal delivery were included in study. Intrauterine contraceptive device was inserted as per o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Obstetrics and gynecology

دوره 116 5  شماره 

صفحات  -

تاریخ انتشار 2010