Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging.
نویسندگان
چکیده
BACKGROUND Soft tissue attenuation is a prominent cause of single-photon emission computed tomography (SPECT) imaging artifacts, which may result in reduced diagnostic accuracy of myocardial perfusion imaging. A method incorporating simultaneously acquired transmission data permits nonuniform attenuation correction and when incorporating scatter correction and resolution compensation may substantially reduce interpretive errors. METHODS AND RESULTS A prospective multicenter trial was performed recruiting patients with angiographically documented coronary disease (n=96) and group of subjects with a low likelihood of disease (n=88). The uncorrected and attenuation/scatter corrected images were read independently, without knowledge of the patient's clinical data. The detection of >/=50% stenosis was similar using uncorrected perfusion data or with attenuation/scatter correction and resolution compensation (visual or visual plus quantitative analysis), 76% versus 75% versus 78%, respectively (P=NS). The normalcy rate, however, was significantly improved with this new methodology, using either the corrected images (86% vs 96%; P=0.011) or with the corrected data and quantitative analysis (86% vs 97%; P=0.007). The receiver operator characteristic curves were also found to be marginally but not significantly higher with attenuation/scatter correction than with tradition SPECT imaging. However, the ability to detect multivessel disease was reduced with attenuation/scatter correction. Regional differences were also noted, with reduced sensitivity but improved specificity for right coronary lesions using attenuation/scatter correction methodology. CONCLUSIONS This multicenter trial demonstrates the initial clinical results of a new SPECT perfusion imaging modality incorporating attenuation and scatter correction in conjunction with 99mTc sestamibi perfusion imaging. Significant improvements in the normalcy rate were noted without a decline in overall sensitivity but with a reduction in detection of extensive coronary disease.
منابع مشابه
Simulation and patient studies of scatter correction in cardiac SPECT imaging
Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...
متن کاملTranslation of Methdology used in Human Myocardial Imaging to a Sheep Model of Acute Myocardial Infarction
Background: Pre-clinical investigation of stem cells for repairing damaged myocardium predominantly used rodents, however large animals have cardiac circulation closely resembling the human heart. The aim of this study was to evaluate whether SPECT/CT myocardial perfusion imaging (MPI) could be used for assessing sheep myocardium following an acute myocardial infarction (MI) and response to int...
متن کاملThe influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...
متن کاملAttenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]
Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...
متن کاملComparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group
Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...