Three-Dimensional Speckle-Tracking Echocardiographic Monitoring of Acute Rejection in Heart Transplant Recipients.
نویسندگان
چکیده
OBJECTIVES This study assessed the use of 3-dimensional (3D) speckle-tracking echocardiography for noninvasive monitoring and diagnosis of acute rejection in heart transplant recipients. METHODS Fifteen heart transplant recipients underwent 32 endomyocardial biopsies; echocardiography was performed within 3 hours before biopsy. Twenty-four biopsies (acute rejection-negative group) showed grade 0 or 1A rejection, and 8 biopsies (acute rejection-positive group) showed grade 1B or higher rejection (based on the International Society for Heart and Lung Transplantation criteria). Two-dimensional, M-mode, pulsed Doppler, and tissue Doppler echocardiography were performed to assess conventional heart structure and function, and 3D full-volume echocardiography was recorded and analyzed. RESULTS Global peak longitudinal strain was significantly lower in the acute rejection-negative group compared to the positive group (mean ± SD, -7.38% ± 1.34% versus -10.88% ± 3.81%; P = .017). Differences in left ventricular global peak radial strain (28.79% ± 10.79% versus 24.32% ± 5.24%; P= .272), global peak circumferential strain (-12.16% ± 4.87% versus -12.61% ± 2.38%; P = .806), and ejection fraction (49.42% ± 12.17% versus 50.68% ± 7.26%; P = .824) between the negative and positive groups were not significant. Significant correlations were observed between the left ventricular ejection fraction and global peak longitudinal, global peak radial, and global peak circumferential (r = -0.72; P < .001; r = 0.60; P < 0.001; and r = -0.69; P < 0.001, respectively). Receiver operating characteristic curve analysis showed that a global peak longitudinal strain cutoff value of less than -9.55% could predict grade 1B or higher rejection with sensitivity of 87.50% and specificity of 54.17%. CONCLUSIONS Three-dimensional speckle-tracking echocardiography-derived global peak longitudinal strain is a useful parameter for detecting acute rejection; thus, 3D speckle-tracking echocardiography can monitor dynamic and acute rejection (≥1B) in heart transplant recipients.
منابع مشابه
Evaluation of myocardial mechanics with three-dimensional speckle tracking echocardiography in heart transplant recipients: comparison with two-dimensional speckle tracking and relationship with clinical variables.
AIMS Two-dimensional speckle-tracking echocardiography (2D-STE) is limited by its inability to track tissue motion in three dimensions. This is particularly relevant in heart transplant recipients, in whom marked translational motion of the transplanted heart is present. We aimed to compare 3-dimensional (3D)- and 2D-STE-derived strain parameters, and to identify clinical features associated wi...
متن کاملEvaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)
The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...
متن کاملRejection Rate in Kidney Transplant Recipients in Kermanshah, Iran: 1989-2016
Background and purpose: Kidney transplant is a major form of renal replacement therapy in many patients at advanced stages of the disease. Transplant rejection is a major complication following kidney transplant that could be reversible or irreversible. The present study was done to investigate the incidence of irreversible kidney transplant rejection. Materials and methods: A retrospective co...
متن کاملUsefulness and limitations of transthoracic echocardiography in heart transplantation recipients
Transthoracic echocardiography is a primary non-invasive modality for investigation of heart transplant recipients. It is a versatile tool which provides comprehensive information about cardiac structure and function. Echocardiographic examinations can be easily performed at the bedside and serially repeated without any patient's discomfort. This review highlights the usefulness of Doppler echo...
متن کاملRemote noninvasive allograft rejection monitoring for heart transplant recipients: study protocol for the novel evaluation with home electrocardiogram and remote transmission (NEW HEART) study
BACKGROUND Acute allograft rejection is a major cause of early mortality in the first year after heart transplantation in adults. Although endomyocardial biopsy (EMB) is not a perfect "gold standard" for a correct diagnosis of acute allograft rejection, it is considered the best available test and thus, is the current standard practice. Unfortunately, EMB is an invasive and costly procedure tha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
دوره 35 6 شماره
صفحات -
تاریخ انتشار 2016