Comparison of Two Canal Preparation Techniques Using Mtwo Rotary Instruments

نویسندگان

  • Faeze Hamze
  • Kiamars Honardar
  • Kiumars Nazarimoghadam
چکیده

INTRODUCTION Root canal preparation is an important process in endodontic therapy. Nickel-titanium (NiTi) rotary file system can be used in single length technique (simultaneous technique) without early coronal enlargement, as well as in crown-down method. The purpose of this in vitro study was to compare single length with crown-down methods' shaping ability using Mtwo NiTi files. MATERIALS AND METHODS Fifteen acrylic-resin blocks containing simulated canals were divided into two experimental groups. In group A, single length technique was used and in group B root canals were prepared by crown-down technique. Pre- and post-preparation canals were photographed in a standardized manner and were superimposed. The inner and outer walls of canal curvature were evaluated at three points (apical, middle and coronal) to determine the greatest change. The data was statistically analyzed using the Student t-test by Statistical Analysis System (SAS) software. RESULTS Statistical analysis revealed that in group B, dentine was equally removed within the canal coronal to the curvature, whereas in group A, the inner wall was predominantly removed (P<0.01). The two groups had no significant difference at the apical and middle points of the canal curvature. CONCLUSION Our in vitro study revealed no significant difference between the single length method and crown-down technique using Mtwo for preparation of apical and middle portion of canal curvature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Single Visit Post Endodontic Pain Using Mtwo Rotary and Hand K-File Instruments: A Randomized Clinical Trial

OBJECTIVES Pain is an unpleasant outcome of endodontic treatment that can be unbearable to patients. Instrumentation techniques may affect the frequency and intensity of post-endodontic pain. This study aimed to compare single visit post endodontic pain using Mtwo (NiTi) rotary and hand K-file instruments. MATERIALS AND METHODS In this randomized controlled trial, 60 teeth with symptomatic ir...

متن کامل

Comparison of apical debris extrusion using a conventional and two rotary techniques

INTRODUCTION Preparation techniques and instruments produce and push debris out of canals. This can induce inflammation within the periapical area. Therefore, instrumentation that causes less extrusion of debris is more desirable. The purpose of this in vitro study was to evaluate the quantity of debris extruded from the apical foramen during root canal preparation by using one hand, and two ro...

متن کامل

Comparison of working length control consistency between hand K-files and Mtwo NiTi rotary system

BACKGROUND The purpose of this study was to investigate the consistency of working length control between hand instrumentation in comparison to engine driven Mtwo nickel-titanium rotary files. MATERIAL AND METHODS Forty extracted maxillary molars were selected and divided onto two parallel groups. The working lengths of the mesiobuccal root canals were estimated. The teeth were fixed in a pha...

متن کامل

Comparison of preparation of curved root canals with Hyflex CM and Revo-S rotary nickel-titanium instruments.

AIM To compare the shaping ability of three different nickel-titanium rotary instruments during the preparation of curved root canals in extracted teeth. METHODOLOGY A total of 60 root canals with curvatures ranging between 25° and 35° were divided into three groups of 20 canals. Based on radiographs taken prior to instrumentation, the groups were balanced with respect to the angle and the ra...

متن کامل

Effectiveness of a manual glide path on the preparation of curved root canals by using Mtwo rotary instruments.

INTRODUCTION Nickel-titanium rotary instruments reduce procedural errors and the time required to finish root canal preparation. The goal of this study was to evaluate the effectiveness of a manual glide path on the preparation of curved root canals with Mtwo rotary system. METHODS Forty buccal root canals with angles of curvature between 25 to 76 degrees were randomly divided into 4 groups (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011