Data-driven approach to generating achievable dose-volume histogram objectives in intensity-modulated radiotherapy planning.

نویسندگان

  • Binbin Wu
  • Francesco Ricchetti
  • Giuseppe Sanguineti
  • Michael Kazhdan
  • Patricio Simari
  • Robert Jacques
  • Russell Taylor
  • Todd McNutt
چکیده

PURPOSE To propose a method of intensity-modulated radiotherapy (IMRT) planning that generates achievable dose-volume histogram (DVH) objectives using a database containing geometric and dosimetric information of previous patients. METHODS AND MATERIALS The overlap volume histogram (OVH) is used to compare the spatial relationships between the organs at risk and targets of a new patient with those of previous patients in a database. From the OVH analysis, the DVH objectives of the new patient were generated from the database and used as the initial planning goals. In a retrospective OVH-assisted planning demonstration, 15 patients were randomly selected from a database containing clinical plans (CPs) of 91 previous head-and-neck patients treated by a three-level IMRT-simultaneous integrated boost technique. OVH-assisted plans (OPs) were planned in a leave-one-out manner by a planner who had no knowledge of CPs. Thus, DVH objectives of an OP were generated from a subdatabase containing the information of the other 90 patients. Those DVH objectives were then used as the initial planning goals in IMRT optimization. Planning efficiency was evaluated by the number of clicks of the "Start Optimization" button in the course of planning. Although the Pinnacle(3) treatment planning system allows planners to interactively adjust the DVH parameters during optimization, planners in our institution have never used this function in planning. RESULTS The average clicks required for completing the CP and OP was 27.6 and 1.9, respectively (p <.00001); three OPs were finished within a single click. Ten more patient's cord + 4 mm reached the sparing goal D(0.1cc) <44 Gy (p <.0001), where D(0.1cc) represents the dose corresponding to 0.1 cc. For planning target volume uniformity, conformity, and other organ at risk sparing, the OPs were at least comparable with the CPs. Additionally, the averages of D(0.1cc) to the cord + 4 mm decreased by 6.9 Gy (p <.0001); averages of D(0.1cc) to the brainstem decreased by 7.7 Gy (p <.005). The averages of V(30 Gy) to the contralateral parotid decreased by 8.7% (p <.0001), where V(30 Gy) represents the percentage volume corresponding to 30 Gy. CONCLUSION The method heralds the possibility of automated IMRT planning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using overlap volume histogram and IMRT plan data to guide and automate VMAT planning: a head-and-neck case study.

PURPOSE To investigate whether an overlap volume histogram (OVH)-driven planning application using an intensity-modulated radiation therapy (IMRT) database can guide and automate volumetric-modulated arc therapy (VMAT) planning for head-and-neck cancer. METHODS Based on comparable head-and-neck dosimetric results between planner-generated VMAT and IMRT plans, an inhouse developed, OVH-driven ...

متن کامل

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

A multiplan treatment-planning framework: a paradigm shift for intensity-modulated radiotherapy.

PURPOSE To describe a multiplan intensity-modulated radiotherapy (IMRT) planning framework, and to describe a decision support system (DSS) for ranking multiple plans and modeling the planning surface. METHODS AND MATERIALS One hundred twenty-five plans were generated sequentially for a head-and-neck case and a pelvic case by varying the dose-volume constraints on each of the organs at risk (...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of radiation oncology, biology, physics

دوره 79 4  شماره 

صفحات  -

تاریخ انتشار 2011