Assessment of the Effect of the Ionic Implantation by Plasma Immersion on the Flexibility of the Nickel-titanium Endodontic Fi
نویسندگان
چکیده
Due to its pseudo elastic behavior, the nickel-titanium (nitinol) alloy has been used in the manufacture of endodontic instruments in recent years, being especially useful for curved canals preparation. Extensive research has been carried out to improve the wear resistance of the nitinol instruments without create modifications in the bulk of the files. The purpose of this work was to measure the flexibility of commercially available type K stainless steel and nickel-titanium endodontic files, submit the nitinol files to plasma immersion ion implantation and assess the treatment effects on the same property. The instruments flexibility was measured throughout the bending moment test at 30 and 45 according to the American Dental Association specification n 28. The hardness of the files was measured before and after treatment by the Vickers method. The instruments surface state was observed throughout scanning electronic microscopy and the surface chemical composition of treated instruments was determined throughout the X-Rays photoelectron spectroscopy. The results found have led to the conclusion that no statistically significant change on the instruments flexibility was observed after the plasma immersion ion implantation. Key-words: endodontic files, nickel-titanium, ionic implantation.
منابع مشابه
Mechanical properties, bioactivity and corrosion resistance of oxygen and sodium plasma treated nickel titanium shape memory alloy
Nickel titanium (NiTi) shape memory alloy is a unique material displaying the shape memory effect and superelastic property making it attractive to the orthopedic field. However, with its high nickel content of∼50%, there is concern on health and safety when this material is implanted inside the human body for a prolonged period of time as toxic nickel ions may leach into the body due to corros...
متن کاملEvaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study
Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...
متن کاملCore–shell titanium dioxide /carbon nanofibers decorated nickel nanoparticles as supports for electrocatalytic oxidation of ethanol
Abstract Recently alcohol fuel cells has been increased consideration because of their environmental friendliness, high energy conversion efficiency and low emissions. Many effort have been made to improve the electro-oxidation performance of alcohols such as methanol, ethanol and propanol. In this work, a new method for ethanol oxidation based on core–shell titanium dioxide / carbon nanofib...
متن کاملCarbon plasma immersion ion implantation of nickel-titanium shape memory alloys.
Nickel-titanium (NiTi) shape memory alloys possess super-elasticity in addition to the well-known shape memory effect and are potentially suitable for orthopedic implants. However, a critical concern is the release of harmful Ni ions from the implants into the living tissues. We propose to enhance the corrosion resistance and other surface and biological properties of NiTi using carbon plasma i...
متن کاملInvestigation of the effect of electrolyte on acoustical behaviour of ceramic coatings produced by method Plasma Electrolytic Oxidation (PEO) on titanium
In this paper, titanium oxide coating (TiO2) was produced on titanium alloy Ti6Al4V by Plasma Electrolytic Oxidation (PEO) Method. Sodium Silicate (Na2SiO3) and Sodium Aluminate (NaAlO2) based electrolytes were selected in PEO process. The effects of concentration of Sodium Aluminate (0, 2.5, 5, 7.5, and 10 g/L) on the microstructure and acoustical behaviour of the formed coatings were studied....
متن کامل