CASE STUDIES Assessment of the Electromagnetic Disturbance of a Glass Fiber Reinforced Composite Fencing Structure

نویسندگان

  • Domenico Asprone
  • Dario Assante
  • Andrea Chiariello
  • Gaetano Manfredi
  • Giovanni Miano
  • Andrea Prota
  • Guglielmo Rubinacci
چکیده

This work addresses the assessment of the electromagnetic disturbance induced by a composite barrier—fencing airport structures—to radio-communication electromagnetic waves. The barrier is composed of glass fiber reinforced polymer GFRP tubular elements installed into a concrete base. Based on the electromagnetic properties of constituent materials, numerical analyses describing the electromagnetic phenomenon were carried out, simulating the barrier submerged into the electromagnetic field of interest. Furthermore, full-scale experimental tests were also performed on samples of the barrier in an anechoic chamber, reproducing the electromagnetic field generated by the radio-communication antennas. Both the numerical and experimental studies confirm that composites and, in particular, GFRPs result in low interference with electromagnetic fields. The main contribution to the interference is generated by the concrete base. However, it may be significantly reduced by using particular strategies, for example, in very high frequency omnidirectional range systems, by placing the concrete basement under the counterpoise level of the antennas. DOI: 10.1061/ ASCE CC.1943-5614.0000121 CE Database subject headings: Fiber reinforced polymer; Glass; Composite materials; Blasting; Fences; Case studies. Author keywords: GFRP composites; Blast protection structures; Electromagnetic disturbance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Assessment of Ultrasonic C-scan and X-ray Radiography Methods for Impact Damage Detection in Glass Fiber Reinforced Polyester Composites

The present study introduces two quantitative parameters to compare the accuracy of ultrasonic C-scan testing and X-ray radiography methods in the damaged area detection under low-velocity impact in polymer-based composites. For this purpose, the hand lay-up technique of composite processing was employed to prepare the composite specimen. A composite specimen consisting of the glass fiber reinf...

متن کامل

Evaluation of Mechanical and Tribological Properties of Glass/Carbon Fiber Reinforced Polymer Hybrid Composite

Polymer matrix composites used in different industrial applications due to their enhanced mechanical properties and lightweight. However, these materials are subjected to friction and wear situations in some industrial and automobile applications. Therefore, there is a need to investigate the wear properties of polymer matrix composite materials. This article emphasizes the dry abrasive wear be...

متن کامل

An Investigation into the Deep Drawing of Fiber-Metal Laminates based on Glass Fiber Reinforced Polypropylene

Abstract   Fiber-metal laminates (FMLs) are new type of composite materials which could improve defects of traditional composites in ductility, formability, impact and damage tolerance. Drawing behavior of a thermoplastic based FML was investigated consisting of glass-fiber reinforced polypropylene composite laminate and aluminum AA1200-O as the core and skin layers, respectively. The effects o...

متن کامل

Experimental investigation of the strength of glass fiber-reinforced concrete exposed to high temperature

This study investigated the effects of high temperature exposure on the compressive, tensile, and flexural strengths of concrete containing glass fiber. A total of 108 cubic specimens (150 mm × 150 mm × 150 mm), cylindrical specimens (300 mm × 150 mm), and prismatic specimens (500 mm × 150 mm × 150 mm) were prepared for compressive, tensile, and flexural strength testing, respectively. The spec...

متن کامل

Effect of length and diameter of fiber reinforced composite post (FRC) on fracture resistance of remaining tooth structure

Introduction: Post and core has been considered for endodontically treated tooth, especially in cases with severe damage crowns. Recently fiber reinforced composite posts (FRC post) have been used in the treatment of endodontically treated teeth. Because the length and diameter of posts are effective in stress distribution, the purpose of this study is to evaluate the effect of length and diame...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010