Application of the Global Positioning System to the Measurement of Overhead Power Transmission Conductor Sag

نویسنده

  • C. Mensah - Bonsu U. Fernández G. T. Heydt Y. Hoverson J. Schilleci B. Agrawal
چکیده

This paper describes a method to directly measure the physical sag of overhead electric power transmission conductors. The method used relies on the Global Positioning System (GPS) used in the differential mode. The direct measurement of sag is a main advantage of the concept. The digital signal processing required is described in detail in a four level configuration. Typical accuracy, response time, problems, strengths and weaknesses of the method are also described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of GPS for Sag Measurement of Overhead Power Transmission Line

Overhead conductor sag may be measured by different methods. In the paper measurement of sag of 66KV power transmission line under shut down conditions at no wind load using standard handheld GPS receiver BT 359 has done. The real time direct measurement of overhead conductor sag is needed for the operation of power transmission system. The measurement of conductor tension, temperature and ambi...

متن کامل

Differential GPS Measurement of Overhead Conductor Sag: Software Implementation

(PSERC). PSERC is a multi-university Center conducting research on challenges facing a restructuring electric power industry and educating the next generation of power engineers. of Entergy-New Orleans. In early stages of the project, Mr. Lance Priez of Entergy supplied needed information. The many useful suggestions of all the industrial advisors are acknowledged. Dale Bradshaw of the Tennesse...

متن کامل

Voltage Sag in Distribution Systems- A review and comparative study (Reasons, Characteristics, Compensations and Detection)

By quick technological advancements in industrial control processes, major industries demand higher power quality. According to IEEE 1159-1995 standard, any problems in voltage, current or freq‌ue‌ncy that lead to the error or malfunctions in electrical equipment are considered as a power quality problem. Among the power quality phenomena, voltage sag has been an important problem for power sys...

متن کامل

Application of Intelligent Water Drops in Transient Analysis of Single Conductor Overhead Lines Terminated to Grid-Grounded Arrester under Direct Lightning Strikes

In this paper, Intelligent water drop algorithm (IWD) is used to analyze single overhead line connected to grid-grounded arrester. In this approach, at first Norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (MoM) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. Finally applying inte...

متن کامل

Transient Analysis of the Single-Conductor Overhead Lines Connected to Grid-Grounded Arrester under Direct Lightning by Means of GA

In this paper, genetic algorithm-based approach for transient analysis of single transmission line connected to arrester is proposed. In this approach, the lightning channel striking the overhead line is first represented by a current source and this source is truncated by a finite set of frequency harmonies in time domain. Norton equivalent circuit viewed across arrester is then computed by me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001