Evaluation of gantry rotation overrun in axial CT scanning

نویسندگان

  • Atsushi Fukuda
  • Pei‐Jan P. Lin
  • Kosuke Matsubara
  • Tosiaki Miyati
چکیده

The purpose of this study was to develop and evaluate a simple method to assess gantry rotation overrun in a single axial CT scanning. The exposure time in the axial scanning was measured at selected nominal rotation times (400, 700, and 1000 ms) using a solid-state detector, the RTI's CT dose profiler (CTDP). CTDP was placed at the isocenter and the radiation dose rate signal (profile) was recorded. Subsequently, the full width of this profile was determined as the exposure time (Taxial). Next, CTDP was positioned on the inner cover of the gantry with a sheet of lead (1 mm thick) placed on top of the detector. Gantry rotation time (Thelical) was determined by the time between two successive radiation peaks during continuous helical scanning. The gantry overrun time (Toverrun) is, thus, determined as Taxial - Thelical. The exposure times in the axial scanning, Taxial, obtained with CTDP for nominal rotation times of 400, 700, and 1000 ms were 409.5, 709.6, and 1008.7 ms, respectively. On the other hand, the measured gantry rotation times, Thelical, were 400.0, 700.3, and 999.8 ms, respectively. Therefore, the overruns were 9.5, 9.3, and 8.9 ms for nominal rotation times of 400, 700, and 1000 ms, respectively. The evaluation of overrun in axial scanning can be accomplished with the measurements of both the exposure time in axial scanning and the gantry rotation time. It is also noteworthy that in this context, overrun implies overexposure in axial scanning, which is still used, particularly, in head CT examination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of dose reduction and influence of gantry rotation time in CT abdomen examinations

Background: Worldwide the computed tomography (CT) scanning is recognized as a high radiation dose modality. This article aimed to estimate the radiation dose reduction and radiogenic risks for adult patients undertaking abdominal CT examinations. Materials and Methods: A total of 128 patients were studied using 2, 4, 16 and 64 slice CT scanners. The patients were divided into two categories: t...

متن کامل

Optimization of the Scan Protocol for the Reduction of Diaphragmatic Motion Artifacts Depicted on CT Angiography: a Phantom Study Simulating Pediatric Patients with Free Breathing

OBJECTIVE This study was designed to optimize the scan protocol of CT angiography to reduce diaphragmatic motion artifacts in pediatric patients with free-breathing. MATERIALS AND METHODS A phantom with twelve tubes with different diameters was constructed. To simulate free-breathing, the phantom was connected to a motor, and the phantom moved along the axis of scan. Scans were performed unde...

متن کامل

Wrist: Different views in CT scanning

This study tests various acquisition and reconstruction protocols for MDCT of the wrist to determine the optimal views in wrist imaging. These views include: wrist in prone position, perpendicularly to CT gantry; wrist in prone position with internal and external deviation of the hand and PA wrist image reformatted in CT workstations along the axis of the scaphoid bone.Among these different vie...

متن کامل

Evaluation of Distal Femoral Rotational Alignment with Spiral CT Scan before Total Knee Arthroplasty (A Study in Iranian Population)

    Background: Evaluating the landmarks for rotation of the distal femur is a challenge for orthopedic surgeons. Although the posterior femoral condyle axis is a good landmark for surgeons, the surgical transepicondylar axis may be a better option with the help of preoperative CT scanning. The purpose of this study was to ascertain relationships among the axes’ guiding distal femur rotational ...

متن کامل

Measurement of image rotation angle in CT for radiotherapy treatment planning

The geometric accuracy of CT images is essential when they are used for planning radiation therapy. In this study, a method of quantitative testing of image rotation in CT is presented, based on the automated analysis of an image of a phantom half-filled with water. A plug-in was written for ImageJ software for automated detection of a water surface in an image and measurement of its angle rela...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014