A Comparative Pulse Accuracy Study of Two Commercially Available Patch Insulin Infusion Pumps

نویسندگان

  • Jenna L Bowen
  • Chris J Allender
چکیده

Background: Patch pumps are a relatively new method of insulin delivery. This study explores the accuracy of patch-pumps by reporting on comparative pulse-accuracy study of two patch pumps. Methods: The accuracy of two patch pumps (Cellnovo, [Cellnovo Ltd., Swansea, UK] and OmniPod® [Ypsomed Ltd, Escrick, UK]) was evaluated micro-gravimetrically. Pulse accuracy was analysed by comparing single and time-averaged pulses for each device. Results: Single-pulses outside accuracy thresholds ±5%, ±10%, ±15%, ±20%, ±25% and ±30% were: Cellnovo; 79.6%, 55.6%, 35.0%, 19.9%, 9.7% and 4.3%; OmniPod; 86.2%, 71.6%, 57.4%, 45.5%, 35.2% and 25.4%. For 10, 20 and 40 pulse-windows mean values outside ±15% accuracy level were: Cellnovo; 7.3%, 1.5% and 0.4%, OmniPod; 37.6%, 31.8% and 25.9. Conclusions: This study showed that not all patch pumps are the same. The pumping mechanisms employed in these pumps play a significant role in the accuracy and precision of such devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative dose accuracy of durable and patch insulin infusion pumps.

BACKGROUND As all major insulin pump manufacturers comply with the international infusion pump standard EN 60601-2-24:1998, there may be a general assumption that all pumps are equal in insulin-delivery accuracy. This research investigates single-dose and averaged-dose accuracy of incremental basal deliveries for one patch model and three durable models of insulin pumps. METHOD For each pump ...

متن کامل

Simulating Insulin Infusion Pump Risks by In-Silico Modeling of the Insulin-Glucose Regulatory System

We present a case study on the use of robustness-guided and statistical model checking approaches for simulating risks due to insulin infusion pump usage by diabetic patients. Insulin infusion pumps allow for a continuous delivery of insulin with varying rates and delivery profiles to help patients self-regulate their blood glucose levels. However, the use of infusion pumps and continuous gluco...

متن کامل

Consensus evidence-based guidelines for use of insulin pump therapy in the management of diabetes as per Indian clinical practice.

The use of insulin pump in diabetes is likely to increase with recent advances in technology. Although the evidence for the superiority of pumps over multiple daily injections (MDI) is inconsistent, data from accumulating uncontrolled studies indicate greater reductions in glycated haemoglobin in patients switching to continuous subcutaneous insulin infusion (CSII) from MDI therapy. Due to the ...

متن کامل

Combining insulin pumps and continuous glucose monitors; where are we to go from here?

Insulin pump development started in 1978, with the first commercially available glucose sensor marketed in 1999. Combining these two instruments is a logical step toward the closed loop. This article discusses three questions: Is pump development complete? How can a pump and a sensor be combined? Can the delay problem associated with the subcutaneous-subcutaneous approach for the closed loop be...

متن کامل

Preoperative Sterilization Preparation of the Shoulder: A Comparative Study Evaluating Gauze Sponge and Commercially Available Applicator Prep Stick

Background: Surgical site infection (SSI) remains a concern in shoulder surgery, especially during arthroplasty. Whilemany studies have explored the characteristics and efficacy of different sterilizing solutions, no study has evaluated themethod of application. The purpose of this study was to compare two popular pre-surgical preparatory applications (two4 x 4 cm gauze sponges and applicator s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2016