Hypofractionated radiotherapy for lung tumors with online cone beam CT guidance and active breathing control
نویسندگان
چکیده
BACKGROUND To study the set-up errors, PTV margin and toxicity of cone beam CT (CBCT) guided hypofractionated radiotherapy with active breathing control (ABC) for patients with non-small cell lung cancer (NSCLC) or metastatic tumors in lung. METHODS 32 tumors in 20 patients were treated. Based on the location of tumor, dose per fraction given to tumor was divided into three groups: 12 Gy, 8 Gy and 6 Gy. ABC is applied for every patient. During each treatment, patients receive CBCT scan for online set-up correction. The pre- and post-correction setup errors between fractions, the interfractional and intrafractional, set-up errors, PTV margin as well as toxicity are analyzed. RESULTS The pre-correction systematic and random errors in the left-right (LR), superior-inferior (SI), anterior-posterior (AP) directions were 3.7 mm and 5.3 mm, 3.1 mm and 2.1 mm, 3.7 mm and 2.8 mm, respectively, while the post-correction residual errors were 0.6 mm and 0.8 mm, 0.8 mm and 0.8 mm, 1.2 mm and 1.3 mm, respectively. There was an obvious intrafractional shift of tumor position. The pre-correction PTV margin was 9.5 mm in LR, 14.1 mm in SI and 8.2 mm in AP direction. After CBCT guided online correction, the PTV margin was markedly reduced in all three directions. The post-correction margins ranged 1.5 to 2.1 mm. The treatment was well tolerated by patients, of whom there were 4 (20%) grade1-2 acute pneumonitis, 3 (15%) grade1 acute esophagitis, 2 (10%) grade1 late pneumonitis and 1 (5%) grade 1 late esophagitis. CONCLUSION The positioning errors for lung SBRT using ABC were significant. Online correction with CBCT image guidance should be applied to reduce setup errors and PTV margin, which may reduce radiotherapy toxicity of tissues when ABC was used.
منابع مشابه
Implementation of single-breath-hold cone beam CT guided hypofraction radiotherapy for lung cancer
BACKGROUND To analyze the feasibility of active breath control (ABC), the lung tumor reproducibility and the rationale for single-breath-hold cone beam CT (CBCT)-guided hypofraction radiotherapy. METHODS Single-breath-hold CBCT images were acquired using ABC in a cohort of 83 lung cancer patients (95 tumors) treated with hypofraction radiotherapy. For all alignments between the reference CT a...
متن کاملAccuracy of Image Guidance Using Free-Breathing Cone-Beam Computed Tomography for Stereotactic Lung Radiotherapy
Movement of the target object during cone-beam computed tomography (CBCT) leads to motion blurring artifacts. The accuracy of manual image matching in image-guided radiotherapy depends on the image quality. We aimed to assess the accuracy of target position localization using free-breathing CBCT during stereotactic lung radiotherapy. The Vero4DRT linear accelerator device was used for the exami...
متن کاملLung tumor motion reproducibility for five patients who received four-fraction VMAT stereotactic ablative body radiotherapy under constrained breathing conditions: a preliminary study
Dear Editor, Several different approaches have been applied to stereotactic hypofractionated radiotherapy for lung tumors, including free breathing, breath-hold, gating, and tracking. Negoro et al. reported that abdominal compression reduced the movement of lung tumors (thereby possibly reducing treatment uncertainty), with portal fluoroscopy being used to measure the tumor movement [1]. Heinze...
متن کاملPhantom based kV-CBCT dose plan calculations for re-planning decision: comparison with CT-based dose plans
s 17th Annual SASRO Meeting, Davos 2013 Physics Oral P01-22 P01 Phantom based kV-CBCT dose plan calculations for re-planning decision: comparison with CT-based dose plans P01 P02 First experimental results of motion mitigation by continuous line scanning P02 P03 Impact of respiratory-correlated CT reconstruction algorithms in the choice of margin definition for free breathing lung treatment P03...
متن کاملImproving iterative 4D CBCT through the use of motion information
In Image-Guided RadioTherapy (IGRT) of lung tumors, patients undergo a 4D CT, on the basis of which their treatment is planned. It is implicitely assumed that their breathing motion will not change much throughout the treatment, and remain close to what it was during the 4D CT acquisition. During the treatment, several cone beam CT acquisitions are performed, and used to re-position the patient...
متن کامل