VD-AUTO-SMASH imaging.
نویسندگان
چکیده
Recently a self-calibrating SMASH technique, AUTO-SMASH, was described. This technique is based on PPA with RF coil arrays using auto-calibration signals. In AUTO-SMASH, important coil sensitivity information required for successful SMASH reconstruction is obtained during the actual scan using the correlation between undersampled SMASH signal data and additionally sampled calibration signals with appropriate offsets in k-space. However, AUTO-SMASH is susceptible to noise in the acquired data and to imperfect spatial harmonic generation in the underlying coil array. In this work, a new modified type of internal sensitivity calibration, VD-AUTO-SMASH, is proposed. This method uses a VD k-space sampling approach and shows the ability to improve the image quality without significantly increasing the total scan time. This new k-space adapted calibration approach is based on a k-space-dependent density function. In this scheme, fully sampled low-spatial frequency data are acquired up to a given cutoff-spatial frequency. Above this frequency, only sparse SMASH-type sampling is performed. On top of the VD approach, advanced fitting routines, which allow an improved extraction of coil-weighting factors in the presence of noise, are proposed. It is shown in simulations and in vivo cardiac images that the VD approach significantly increases the potential and flexibility of rapid imaging with AUTO-SMASH.
منابع مشابه
Improved high resolution imaging with 4-element liquid nitrogen phased array coil and VD-AUTO-SMASH at 1.5T
W. Kwok, Z. You, J. Zhong University of Rochester, Rochester, NY, United States Synopsis We have recently developed liquid-nitrogen (LN2) cooled phased array RF coils that improve SNR significantly over similar room-temperature array coils and provide larger field-of-view coverage over single coils. In this study, we investigate the feasibility of combining LN2 phased array coils with parallel ...
متن کاملAUTO-SMASH: a self-calibrating technique for SMASH imaging. SiMultaneous Acquisition of Spatial Harmonics.
Recently a new fast magnetic resonance imaging strategy, SMASH, has been described, which is based on partially parallel imaging with radiofrequency coil arrays. In this paper, an internal sensitivity calibration technique for the SMASH imaging method using self-calibration signals is described. Coil sensitivity information required for SMASH imaging is obtained during the actual scan using cor...
متن کاملParallel Imaging: The Basics
• Basic Parallel MR Concept (1987-1990) phase array combining sensitivity encoding & hybrids (sub-encoding) • Practical implementations (1997-1999) SMASH: k-space approach SENSE: image domain • Optimization (1999-current) auto-calibration matrix inverse conditioning coil optimization • Extensions (2000-current) generalized SMASH 2-d SENSE & multi-slice arbitrary k-space • Applications (2000-cur...
متن کاملAccelerated cardiac imaging using the SMASH technique.
SMASH (SiMultaneous Acquisition of Spatial Harmonics) was recently introduced as a novel rapid-imaging technique. The SMASH technique uses a partially parallel acquisition strategy, using spatial information from a radiofrequency coil array to accelerate imaging. This study constitutes the first application of SMASH to cardiac magnetic resonance imaging. The increased imaging speed provided by ...
متن کاملEE591 Project Auto-calibrating SENSE
In SMASH-like (SMASH: SiMultaneous Acquisition of Spatial Harmonics,[1]) parallel imaging, the reconstruction function can easily be calculated by fitting real-time data with a small number of additional k-space lines without knowing the exact coil sensitivity distribution. In SENSE-like (SENSE: SENSitivity Encoding,[2]) parallel imaging, sensitivity maps are always required in order to determi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 45 6 شماره
صفحات -
تاریخ انتشار 2001