Wavefront aberration outcomes of LASIK for high myopia and high hyperopia.

نویسنده

  • Konrad Pesudovs
چکیده

PURPOSE To determine the higher order aberrations at the corneal first surface after conventional LASIK for high myopia and high hyperopia. METHODS This was a retrospective study using a convenience sample with subjects divided into five groups by level of refractive correction. Group 1 were normals, having no eye disease or previous surgery, but may have had refractive error. Group 2 had low myopia (-1.00 to -5.87 D), group 3 high myopia (> 6.00 D), group 4 low hyperopia (+1.00 to +3.87 D), and group 5 high hyperopia (> 4.00 D). LASIK was performed using a Technolas 217 laser. Corneal topography was taken with Orbscan II, and Placido data exported to VOLPro software v6.71. Wavefront aberrations were determined for a 6.0-mm pupil. RESULTS The study included 264 subjects-group 1 (normal), n=204; group 2 (low myopia), n=20; group 3 (high myopia), n=20; group 4 (low hyperopia), n=10; and group 5 (high hyperopia), n=10. The spherical equivalent refractive error corrected (mean +/-SD) was 0.00 +/- 0.00 D in group 1, -3.92 +/- 1.47 D in group 2, -9.53 +/- 2.06 D in group 3, +2.49 +/- 0.51 D in group 4, and +5.54 +/- 1.22 D in group 5. The total higher order root-mean-square (RMS) wavefront aberration was 0.38 +/- 0.07 microm in group 1, 0.69 +/- 0.22 microm in group 2, 1.36 +/- 1.79 microm in group 3, 0.64 +/- 0.34 microm in group 4, and 1.76 +/- 0.54 microm in group 5. Spherical aberration was 0.25 +/- 0.06 mcirom in group 1, 0.45 +/- 0.11 microm in group 2, 0.64 +/- 0.29 microm in group 3, -0.11 +/- 0.15 microm in group 4, and -0.56 +/- 0.22 microm in group 5. The refractive correction (Rx) was highly correlated to total higher order RMS for myopic correction higher order RMS = 0.38 - 0.07 Rx, R2=0.52, and for hyperopic correction higher order RMS = 0.18 + 0.28 Rx, R2 = 0.75. CONCLUSIONS Conventional LASIK increases all corneal higher order aberrations with induced aberrations increasing with the magnitude of refractive correction. High refractive corrections, both myopic (>6.00 D) and hyperopic (>5.00 D), can lead to very high levels of corneal higher order aberrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Six-month clinical outcomes in LASIK for high myopia with aspheric «aberration neutral» ablations using the AMARIS laser system

Laser corneal refractive surgery is based on the use of a laser (typically an excimer one) to change the corneal curvature to compensate for refractive errors of the eye1. It has become the most successful technique, mainly due to the submicron precision and the high repeatability of the ablation of the cornea accompanied by minimal side effects. One of the most significant side-effects in myop...

متن کامل

Total and corneal optical aberrations induced by laser in situ keratomileusis for hyperopia.

PURPOSE To evaluate changes induced by standard laser in situ keratomileusis (LASIK) for hyperopia on total and corneal optical quality. METHODS Total and corneal aberrations were measured before and after standard hyperopic LASIK in 13 eyes (preoperative spherical equivalent refractive error +3.17 +/- 1.10 D). The Chiron Technolas 217C laser with PlanoScan was used. Total aberrations (measur...

متن کامل

The Changes of Posterior Corneal Surface and High-Order Aberrations after Refractive Surgery in Moderate Myopia

PURPOSE To compare forward shift of posterior corneal surface and higher-order aberration (HOA) changes after LASIK, LASEK, and wavefront-guided LASEK surgery in moderate myopia METHODS One hundred eighty four eyes undergoing LASIK, LASEK and wavefront-guided LASEK with VISX STAR S4 were included in this study. The posterior corneal elevation was measured with Orbscan before, 2 and 4 months a...

متن کامل

Clinical investigation of off-flap epi-LASIK for moderate to high myopia.

PURPOSE To compare the clinical outcome of on-flap and off-flap epi-LASIK for moderate to high myopia. METHODS This prospective, observer-masked, randomized study included 62 eyes of 31 patients with myopia who underwent off-flap epi-LASIK (epikeratome; Moria, Antony, France) in one eye (off-flap group) and on-flap epi-LASIK in the contralateral eye (on-flap group). Corneal ablation was perfo...

متن کامل

Visual Quality after Wavefront-Guided LASIK for Myopia

This study evaluated the visual quality after wavefront-guided laser in situ keratomileusis (LASIK) for treating myopia. Thirty-two eyes with moderate myopia (-5.78 - -2.17D) and 25 eyes with high myopia (-7.78 - -6.17D) were prospectively reviewed. The contrast sensitivity (CS), glare and the total higher order aberrations (HOA) were measured before and 1 week, 1 month and 2 months after LASIK...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 21 5  شماره 

صفحات  -

تاریخ انتشار 2005