Studies on respiratory humidity. II. Humidity in anesthetic circuits and water loss via anesthesia systems.
نویسنده
چکیده
Through the use of an automatic photo tube dew-point hygrometer, the author succeeded in measuring dew point of gas flows continuously in anesthetic circuits. Simultaneous thermometries were done on the nasal or oral mucosa, on the respiratory gas flows in the anesthetic mask or the endotracheal tube, and on the gas in the inhaling conduit. Experiments were performed on ten adults patients undergoing various types of surgery under general inhalation anesthesia. Anesthetic technics were varied intentionally during the measurements. Thus, both absolute and relative humidities of exhaled and inhaled gases, and respiratory water and heat losses were calculated under various anesthetic conditions, and physiological and clinical considerations were discussed. The conclusions obtained from this research are as follows: (1) When a non-rebreathing system is applied, moisture content of exhaled gas is minimal, and respiratory losses of both water and heat are maximum. With a semi-closed circle method, according to decreasing fresh gas flows, the humidity of the inspiratory and expiratory gases becomes higher, and both heat and water losses through respiration are lessened. When a closed circle method, with carbon dioxide absorption, is employed, temperature and humidity of gas in the inhaling conduit are highest, and the expired gas offers the maximum temperature and moisture contenL Both water and heat losses from anesthesia become minimal when administered in a closed system. (2) While the water and heat that a patient loses through respiration increase with increasing breathing capacity, they are still small parts of the total water and heat losses of the patient. Water and heat losses via anesthesia systems are not so predominant in maintaining water balance and heat regulation of patients during anesthesia and surgery. ∗PMID: 14497443 [PubMed indexed for MEDLINE] Copyright c ©OKAYAMA UNIVERSITY MEDICAL SCHOOL Acta Med. Okayama 15, (1961) STUDIES ON RESPIRATORY HUMIDITY II. HUMIDITY IN ANESTHETIC CIRCUITS AND WATER LOSS VIA ANESTHESIA SYSTEMS
منابع مشابه
Cockroaches breathe discontinuously to reduce respiratory water loss.
The reasons why many insects breathe discontinuously at rest are poorly understood and hotly debated. Three adaptive hypotheses attempt to explain the significance of these discontinuous gas exchange cycles (DGCs), whether it be to save water, to facilitate gas exchange in underground environments or to limit oxidative damage. Comparative studies favour the water saving hypothesis and mechanist...
متن کاملComparison of the temperature and humidity in the anesthetic breathing circuit among different anesthetic workstations
BACKGROUND For patients undergoing general anesthesia, adequate warming and humidification of the inspired gases is very important. The aim of this study was to evaluate the differences in the heat and moisture content of the inspired gases with low-flow anesthesia using 4 different anesthesia machines. METHODS The patients were divided into 11 groups according to the anesthesia machine used ...
متن کاملValidation of the doubly labeled water method under low and high humidity to estimate metabolic rate and water flux in a tropical snake (Boiga irregularis).
This study uses indirect calorimetry to assess the effects of humidity on the accuracy of the doubly labeled water (DLW) technique to predict metabolic rate and water flux in brown treesnakes (Boiga irregularis). The DLW technique accurately predicted total water efflux in brown treesnakes under low-humidity conditions and found that the total number of water molecules exchanged with the enviro...
متن کاملThe impact of humidity on evaporative cooling in small desert birds exposed to high air temperatures.
Environmental temperatures that exceed body temperature (Tb) force endothermic animals to rely solely on evaporative cooling to dissipate heat. However, evaporative heat dissipation can be drastically reduced by environmental humidity, imposing a thermoregulatory challenge. The goal of this study was to investigate the effects of humidity on the thermoregulation of desert birds and to compare t...
متن کاملEfficiency of cold passover and heated humidification under continuous positive airway pressure.
Cold passover and heated humidifiers are employed for the prevention of side-effects associated with continuous positive airway pressure (CPAP) treatment. However, to date, it has not been possible to separately measure the humidity of inspired and expired air. The aim of this study was to compare the relative humidity of the inspired air and the water loss during respiration between cold passo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta medicinae Okayama
دوره 15 شماره
صفحات -
تاریخ انتشار 1961