Assessment of workplace air concentrations of formaldehyde during and before working hours in medical facilities
نویسندگان
چکیده
Workplace air concentrations of formaldehyde (FA) in medical facilities where FA and FA-treated organs were stored and handled were measured before and during working hours and assessed by the official method specified by Work Environment Measurement Law. Sixty-percent of the total facilities examined were judged as inappropriately controlled work environment. The concentrations of FA before working hours by spot sampling were found to exceed 0.1 ppm in some facilities, and tended to increase with increasing volume of containers storing FA and FA-treated materials. Regression analysis revealed that logarithmic concentrations of FA during working hours by the Law-specified analytical method were highly correlated with those before working hours by spot sampling, suggesting the importance for appropriate storing methods of FA and FA-treated materials. The concentrations of FA during working hours are considered to be lowered by effective ventilation of FA-contaminated workplace air and appropriate storage of FA and FA-treated materials in plastic containers in the medical facilities. In particular, such improvement by a local exhaust ventilation system and tightly-sealed containment of FA-treated material were urgently needed for the dissecting room where FA-treated cadavers were prepared and handled for a gross anatomy course in a medical school.
منابع مشابه
Assessment of VOCs, PM10, and Formaldehyde Exposure in the Hair Salons of South Korea
Introduction: In hair salons, workers and customers are exposed to high concentrations of several chemical compounds used during the working environment. Volatile Organic Compounds (VOCs), particulate matter (PM10), nitrogen dioxide (NO2), sulfur dioxide (SO2), carbon monoxide (CO), and formaldehyde are the major chemicals that alter the indoor air quality. This study aimed to assess the indoor...
متن کاملExposure to Formaldehyde during Sterilization in Some Manufactures and Assessing Its Absorption by Zeolites
Background: Formaldehyde is one of the most serious air contaminant that can be found everywhere. Some of the source of formaldehyde include product of building materials, decorated materials, cigarette smoke, etc. Aldehydes compounds especially formaldehyde are used as disinfectants for sterilization in different industries. In this study we measured formaldehyde workplace exposure with NIOS...
متن کاملBiological Monitoring of Healthcare Workers Exposed to Antineoplastic Drugs: Urinary Assessment of Cyclophosphamide and Ifosfamide
Exposure of health care workers to antineoplastic drugs and subsequent adverse health effects is still an open issue. Very little has been studied on the extent of occupational exposure and handling conditions of antineoplastic drugs in Iran. We aimed to determine cyclophosphamide and ifosfamide concentrations in the urine samples of oncology healthcare workers. In addition, we assessed workpla...
متن کاملBiological Monitoring of Healthcare Workers Exposed to Antineoplastic Drugs: Urinary Assessment of Cyclophosphamide and Ifosfamide
Exposure of health care workers to antineoplastic drugs and subsequent adverse health effects is still an open issue. Very little has been studied on the extent of occupational exposure and handling conditions of antineoplastic drugs in Iran. We aimed to determine cyclophosphamide and ifosfamide concentrations in the urine samples of oncology healthcare workers. In addition, we assessed workpla...
متن کاملFormaldehyde as Screen Printing Indoor Pollutant
The presence of formaldehyde in indoor air samples has been detected in five screen printing facilities of Novi Sad, Serbia. Air was sampled five times during one working week for each screen printing facility. The sampling was conducted continuously during 4 hours. The concentrations of formaldehyde were determined by UV-VIS spectrometry at 580 nm. The average concentrations of formaldehyde we...
متن کامل