A small volume procedure for viral concentration from water.

نویسندگان

  • Brian R McMinn
  • Asja Korajkic
چکیده

Small-scale concentration of viruses (sample volumes 1-10 L, here simulated with spiked 100 ml water samples) is an efficient, cost-effective way to identify optimal parameters for virus concentration. Viruses can be concentrated from water using filtration (electropositive, electronegative, glass wool or size exclusion), followed by secondary concentration with beef extract to release viruses from filter surfaces, and finally tertiary concentration resulting in a 5-30 ml volume virus concentrate. In order to identify optimal concentration procedures, two different electropositive filters were evaluated (a glass/cellulose filter [1MDS] and a nano-alumina/glass filter [NanoCeram]), as well as different secondary concentration techniques; the celite technique where three different celite particle sizes were evaluated (fine, medium and large) followed by comparing this technique with that of the established organic flocculation method. Various elution additives were also evaluated for their ability to enhance the release of adenovirus (AdV) particles from filter surfaces. Fine particle celite recovered similar levels of AdV40 and 41 to that of the established organic flocculation method when viral spikes were added during secondary concentration. The glass/cellulose filter recovered higher levels of both, AdV40 and 41, compared to that of a nano-alumina/glass fiber filter. Although not statistically significant, the addition of 0.1% sodium polyphosphate amended beef extract eluant recovered 10% more AdV particles compared to unamended beef extract.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement

Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...

متن کامل

Concentration of enteroviruses from estuarine water.

Pleated cartridge filters readily adsorb viruses in estuarine water at low pH containing aluminum chloride. Adsorbed viruses are efficiently recovered by treating filters with glycine buffer at high pH. By using these procedures, it was possible to recover approximately 70% of the poliovirus added to 400 liters of estuarine water in 3 liters of filter eluate. Reconcentration of virus in the fil...

متن کامل

Serological survey of Small ruminant morbillivirus (SRM) infection of slaughtered Water Buffaloes (Bubalus bubalis) in Ahvaz abattoir in south of Iran

Pest des petits ruminants (PPR) is one of the important viral diseases of goats and sheep. The viral agent of PPR, Small ruminant morbillivirus (SRM), has been shown to infect several species among domestic and wild ruminants. In order to investigate the occurrence of SRM infection in Water Buffalo (Bubalus bubalis), blood samples were collected from 150 buffaloes (98 males, 52 females) referre...

متن کامل

Using a special empirical model to estimate sediment yield of Koohbord dam watershed in Kohgilouyeh County

Extended abstract Koohbord dam watershed with a total area of 38.29 square kilometers in Kohgiluyeh and Boyerahmad province is one of the watersheds without sedimentation data, which requires the use of empirical models to estimate the sediment for estimating sediment, so the results obtained through data is the basis of the management plans of dam watershed. In this research, using base maps ...

متن کامل

Analysis of Gasketed-plate Heat Exchanger Performance Using Nanofluid

A heat exchanger using nanofluid needs to operate at optimum mass concentration level to get the maximum heat transfer performance. A numerical analysis is performed on the heat transfer and pressure drop of water-based γ-Al2O3 nanofluid gasketed-plate heat exchanger to specify its optimum conditions. Cold water will be heated by γ-Al2O3/water nanofluid. The results showed that optimal volume c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of visualized experiments : JoVE

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2015