Sentinel lymph node biopsy for breast cancer using methylene blue dye manifests a short learning curve among experienced surgeons: a prospective tabular cumulative sum (CUSUM) analysis

نویسندگان

  • Jeffrey M East
  • Christopher SP Valentine
  • Emil Kanchev
  • Garfield O Blake
چکیده

BACKGROUND The benefits of sentinel lymph node biopsy (SLNB) for breast cancer patients with histologically negative axillary nodes, in whom axillary lymph node dissection (ALND) is thereby avoided, are now established. Low false negative rate, certainly with blue dye technique, mostly reflects the established high inherent accuracy of SLNB and low axillary nodal metastatic load (subject to patient selection). SLN identification rate is influenced by volume, injection site and choice of mapping agent, axillary nodal metastatic load, SLN location and skill at axillary dissection. Being more subject to technical failure, SLN identification seems to be a more reasonable variable for learning curve assessment than false negative rate. Methylene blue is as good an SLN mapping agent as Isosulfan blue and is much cheaper. Addition of radio-colloid mapping to blue dye does not achieve a sufficiently higher identification rate to justify the cost. Methylene blue is therefore the agent of choice for SLN mapping in developing countries. The American Society of Breast Surgeons recommends that, for competence, surgeons should perform 20 SLNB but admits that the learning curve with a standardized technique may be "much shorter". One appropriate remedy for this dilemma is to plot individual learning curves. METHODS Using methylene blue dye, experienced breast surgeons performed SLNB in selected patients with breast cancer (primary tumor < 5 cm and clinically negative ipsilateral axilla). Intraoperative assessment and completion ALND were performed for standardization on the first 13 of 24 cases. SLN identification was plotted for each surgeon on a tabular cumulative sum (CUSUM) chart with sequential probability ratio test (SPRT) limits based on a target identification rate of 85%. RESULTS The CUSUM plot crossed the SPRT limit line after 8 consecutive, positively identified SLN, signaling achievement of an acceptable level of competence. CONCLUSION Tabular CUSUM charting, based on a justified choice of parameters, indicates that the learning curve for SLNB using methylene blue dye is completed after 8 consecutive, positively identified SLN. CUSUM charting may be used to plot individual learning curves for trainee surgeons by applying a proxy parameter for failure in the presence of a mentor (such as failed SLN identification within 15 minutes).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inappropriate cervical injection of radiotracer for sentinel node mapping in a uterine cervix cancer patient: importance of lymphoscintigraphy and blue dye injection

Herein, we report a case of sentinel lymph node mapping in a uterine cervix cancer patient, referring to the nuclear medicine department of our institute. Lymphoscintigraphy images showed inappropriate intra‐cervical injection of radiotracer. Blue dye technique was applied for sentinel lymph node mapping, using intra‐cervical injection of methylene blue. Two blue/cold sentinel lymph nodes, with...

متن کامل

Sentinel lymph node mapping in breast cancer.

Sentinel lymph node (SLN) biopsy is a rapidly emerging treatment option for patients with early-stage invasive breast cancer and a clinically negative axilla. In the era of mammographic detection, SLN biopsy has the potential to eliminate axillary dissection for the enlarging cohort of breast cancer patients who are node-negative. Using radioisotope, blue dye, or both methods, experienced surge...

متن کامل

Sentinel lymph node biopsy using dye alone method is reliable and accurate even after neo-adjuvant chemotherapy in locally advanced breast cancer - a prospective study

BACKGROUND Sentinel lymph node biopsy (SLNB) is now considered a standard of care in early breast cancers with N0 axillae; however, its role in locally advanced breast cancer (LABC) after neo-adjuvant chemotherapy (NACT) is still being debated. The present study assessed the feasibility, efficacy and accuracy of sentinel lymph node biopsy (SLNB) using "dye alone" (methylene blue) method in pati...

متن کامل

A Study of Sentinel Lymph Node Biopsy in Early Breast Cancer using Methylene Blue in a Teritary Care Hospital in South India

Background: Sentinel lymph node biopsy in early breast cancer performed by intraparenchymal or intradermal injection of blue dye and/or radioactive colloid remains a highly acceptable method of identifying sentinel nodes largely because of its success rate. Aim: 1. To assess the efficacy of sentinel lymph node biopsy in detecting axillary metastases in cases of node negative early breast cancer...

متن کامل

Sentinel Lymph Node Biopsy For Breast Cancer Using Methylene Blue

Original Article Aims & objectives :Carcinoma breast is the most common malignancy in females and is the leading cause of the death in their middle age. 1/3rd of patients present with locally advanced disease with distant metastasis at the time of their initial diagnosis. Sentinel lymph node (SLN) biopsy is a reliable and minimally invasive diagnostic method to determine the regional nodal stat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Surgery

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2009