Microbial Contamination of Suction Tubes Attached to Suction Instrument and Its Preventive Methods

نویسندگان

  • Katsuhiro Yorioka
  • Shigeharu Oie
چکیده

We investigated the microbial contamination of suction tubes attached to wall-type suction instrument. Microbial contamination of suction tubes used for endoscopy or sputum suction in wards was examined before and after their disinfection. In addition, disinfection and washing methods for suction tubes were evaluated. Suction tubes (N=33) before disinfection were contaminated with 102-108 colony-forming units (cfu) / tube. The main contaminants were Pseudomonas aeruginosa, Acinetobacter baumannii, and Stenotrophomonas maltophilia. The suction tubes were disinfected with sodium hypochlorite (N=11) or hot water (N=11), or using an automatic tube cleaner (N=11). After 2-hour immersion in 0.1% (1,000 ppm) sodium hypochlorite, 103-107cfu/tube of bacteria were detected in all 11 tubes examined. After washing in hot running water (65C), 103-107cfu / tube were detected in 3 of 11 examined tubes. The bacteria detected in the suction tubes after disinfection with sodium hypochlorite or hot water were P. aeruginosa, A.baumannii, and S.maltophilia. On the other hand, after washing with warm water (40C) using the automatic tube cleaner, the contamination were < 20 cfu / tube (lower detection limit: 20 cfu / tube) in all 11 tubes examined. These results suggest the usefulness of washing using the automatic tube cleaners.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microbial contamination of suction tubes attached to suction instruments and preventive methods.

We investigated the microbial contamination of suction tubes attached to wall-type suction instruments. Microbial contamination of suction tubes used for endoscopy or sputum suction in hospital wards was examined before and after their disinfection. In addition, disinfection and washing methods for suction tubes were evaluated. Suction tubes (n=33) before disinfection were contaminated with 10(...

متن کامل

Comparison of the prevalence of pericardial effusion and cardiac tamponade after cardiac surgery with and without chest tube suction in patients referred to Chamran hospital, Isfahan

Background: Pericardial effusion is one of the most important complications of cardiac surgeries. Administration of a low-power suction to the mediastinal or pleural chest tube of patients helps better and constant drainage of pericardial or pleural secretions after surgeries. This technique might change the secretion and discharges of patients and might change the outcomes of surgeries. Metho...

متن کامل

بررسی میزان شیوع عفونت های باکتریایی در دستگاه تنفس شیرخواران تحت تهویه مکانیکی در یکی از بیمارستانهای علومزشکی تهران سال 76-74

The present is a descriptive study aimed at an investigtion into the incidence of bacterial infections in the respiratory system of infans under mechanical ventilation. Use of this instrument is inevitable in cases of respiratory failure or delay, and the air passage should be kept clean by means of a trachea suction thus the problem of pulmonary infection due to handling and entering of partic...

متن کامل

Uphill grime: process improvement in surgical instrument cleaning.

After its investigation of cross-contamination from arthroscopic shavers, the US Food and Drug Administration issued an alert to hospitals about medical device reprocessing methods. In response to this, a team of risk management and instrument room personnel at a university hospital undertook a project that tested the manufacturer's recommended cleaning methods for surgical instruments with the...

متن کامل

Evaluation of Bacterial Contamination in a Clinical Environment

BACKGROUND Although the contamination of the dental environment and personnel through aerosol contamination is a definite source of cross contamination; there is little data on the microbial involvement of the dental environment. MATERIALS AND METHODS A total of 100 samples were taken from various inanimate surfaces in the clinical dental setting were collected aseptically by rotating sterile...