Study of He Rabi nutations by optically-pumped cesium magnetometers

نویسندگان

  • Hans-Christian Koch
  • Georg Bison
  • Zoran Dragan Grujić
  • Werner Heil
  • Malgorzata Kasprzak
  • Paul Knowles
  • Andreas Kraft
  • Anatoly Pazgalev
  • Allard Schnabel
  • Jens Voigt
  • Antoine Weis
چکیده

We describe a method for recording the Rabi nutation of nuclear spin polarized He by optically pumped cesium magnetometers. The measurement is performed by detecting the time-dependent magnetic field produced by the He magnetization. The observed signals are compared to theoretical models and the results are used to precisely trace the evolution of the magnetization. This procedure represents a convenient way to control and measure the Rabi flip angle and the degree of spin polarization in experiments using He magnetometers. The method requires only very coarse knowledge of the applied magnetic field’s magnitude.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Sample Rate Optically Pumped Helium Magnetometer

Optically pumped helium magnetometers are important instruments whichhave many applications in military, mass spectroscopy and space applications. In thispaper, the working principles of helium magnetometers have been explained. There isalso an introduction of a new method for finding the resonant frequency, which hasadvantages to the typical method such as more sample r...

متن کامل

Measurement of the Earth’s Magnetic Field Vector based on zero field finding algorithm using optically pumped magnetometers

Atomic magnetometers have found widespread applications in precise measurement of the Earth’s magnetic field due to their high sensitivity. In these measurements, various methods have been utilized to compensate the Earth’s magnetic field in an unshielded environment. In this paper, we have proposed a method based on finding the minimum resonance frequency (corresponding to minimum magnetic fie...

متن کامل

Investigation of the intrinsic sensitivity of a He/Cs magnetometer

We report on extensive studies on the intrinsic sensitivity of a combined He/Cs magnetometer. The magnetometer relies on the detection of the free spin precession of nuclear spin polarized He by optically pumped cesium magnetometers. We characterize the relevant processes involved in the detection and quantify their impact on the total sensitivity of the magnetometer. An expression is derived t...

متن کامل

Design and performance of an absolute He/Cs magnetometer

We report on the design and performance of a highly sensitive combined He/Cs magnetometer for the absolute measurement of magnetic fields. The magnetometer relies on the magnetometric detection of the free spin precession of nuclear spin polarized He gas by optically pumped cesium magnetometers. We plan to deploy this type of combined magnetometer in an experiment searching for a permanent elec...

متن کامل

The NIST Optically Pumped Cesium Frequency Standard

The National Institute of Standards and Technology is developing an optically pumped, cesium-beam primary frequency standard. The design follows from an analysis of systematic errors found in cesium beam standards. The details of the design, performance of major subsystems, and preliminary tests of the standard are presented.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017