n vivo optical coherence tomography detection of ifferences in regional large airway smoke inhalation nduced injury in a rabbit model

نویسندگان

  • atthew Brenner
  • Navneet Narula
  • Zhongping Chen
چکیده

Smoke inhalation injury causes acute airway injury that may result in airway compromise with significant morbidity and mortality. We investigate the ability of high resolution endobronchial optical coherence tomography OCT to obtain real-time images for quantitatively assessing regional differences between upper tracheal versus lower tracheal and bronchial airway injury responses to smoke inhalation in vivo using a prototype spectral domain SLD -OCT system we constructed, and flexible fiber optic probes. 33 New Zealand White rabbits are intubated and mechanically ventilated. The treatment groups are exposed to inhaled smoke. The OCT probe is introduced through the endotracheal tube and maintained in place for 5 to 6 h. Images of airway mucosa and submucosa are obtained at baseline and at specified intervals postexposure. Starting within less than 15 min after smoke inhalation, there is significant airway thickening in the smokeexposed animals. This is maintained over 5 h of imaging studies. The lower tracheal airway changes, correlating closely with carboxyhemoglobin levels, are much greater than upper tracheal changes. Significant differences are seen in lower trachea and bronchi after acute smoke inhalation compared to upper trachea as measured in vivo by minimally invasive OCT. OCT is capable of quantitatively detecting regional changes in airway swelling following inhalation injury. © 2008 Society of Photo-Optical Instrumentation Engineers. DOI: 10.1117/1.2939400

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo optical coherence tomography detection of differences in regional large airway smoke inhalation induced injury in a rabbit model.

Smoke inhalation injury causes acute airway injury that may result in airway compromise with significant morbidity and mortality. We investigate the ability of high resolution endobronchial optical coherence tomography (OCT) to obtain real-time images for quantitatively assessing regional differences between upper tracheal versus lower tracheal and bronchial airway injury responses to smoke inh...

متن کامل

etection of acute smoke-induced airway injury n a New Zealand white rabbit model using optical oherence tomography

hongping Chen niversity of California—Irvine eckman Laser Institute Abstract. Optical coherence tomography OCT is a micron scale high-resolution optical technology that can provide real-time in vivo images noninvasively. The ability to detect airway mucosal and submucosal injury rapidly will be valuable for a range of pulmonary applications including assessment of acute inhalation smoke and bur...

متن کامل

In vivo early detection of smoke-induced airway injury using three-dimensional swept-source optical coherence tomography.

We report on the feasibility of rapid, high-resolution, 3-D swept-source optical coherence tomography (SSOCT) to detect early airway injury changes following smoke inhalation exposure in a rabbit model. The SSOCT system obtains 3-D helical scanning using a microelectromechanical system motor-based endoscope. Real-time 2-D data processing and image display at the speed of 20 frames/s are achieve...

متن کامل

Quantification of airway thickness changes in smoke-inhalation injury using in-vivo 3-D endoscopic frequency-domain optical coherence tomography

Smoke inhalation injury is frequently accompanied by cyanide poisoning that may result in substantial morbidity and mortality, and methods are needed to quantitatively determine extent of airway injury. We utilized a 3-D endoscopic frequency-domain optical coherence tomography (FD-OCT) constructed with a swept-source laser to investigate morphological airway changes following smoke and cyanide ...

متن کامل

In vivo detection of inhalation injury in large airway using three-dimensional long-range swept-source optical coherence tomography.

We report on the feasibility of using long-range swept-source optical coherence tomography (OCT) to detect airway changes following smoke inhalation in a sheep model. The long-range OCT system (with axial imaging range of 25 mm) and probe are capable of rapidly obtaining a series of high-resolution full cross-sectional images and three-dimensional reconstructions covering 20-cm length of trache...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008