Inherent change in MammoSite applicator three-dimensional geometry over time

نویسندگان

  • Subhakar Mutyala
  • Walter Choi
  • Atif J Khan
  • Ravi Yaparpalvi
  • Alexandra J Stewart
  • Phillip M Devlin
چکیده

Accelerated partial breast irradiation is commonly done with the MammoSite applicator, which requires symmetry to treat the patient. This paper describes three cases that were asymmetric when initially placed and became symmetric over time, without manipulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proof of Symmetric Dose Distribution in Mammosite Applicator in Breast Brachytherapy with MCNP Simulation

Introduction: In brachytherapy treatments, high-dose sources are used in interstitial placement. In this paper, the modeling of a common breast cancer treatment applicator called MammoSite is done by the Monte Carlo simulation code. Then, to study and calculate the amount of doses in the breast and the dose rate of the organs at risk of radiation, including: lungs, ribs and ski...

متن کامل

Calculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP

Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...

متن کامل

Three‐dimensional quantitative dose reduction analysis in MammoSite balloon by Monte Carlo calculations

Current treatment planning systems (TPSs) for partial breast irradiation using the MammoSite brachytherapy applicator (Cytyc Corporation, Marlborough, MA) often neglect the effect of inhomogeneity, leading to potential inaccuracies in dose distributions. Previous publications either have studied only a planar dose perturbation along the bisector of the source or have paid little attention to th...

متن کامل

Dose volume histogram analysis of normal structures associated with accelerated partial breast irradiation delivered by high dose rate brachytherapy and comparison with whole breast external beam radiotherapy fields

PURPOSE To assess the radiation dose delivered to the heart and ipsilateral lung during accelerated partial breast brachytherapy using a MammoSite applicator and compare to those produced by whole breast external beam radiotherapy (WBRT). MATERIALS AND METHODS Dosimetric analysis was conducted on patients receiving MammoSite breast brachytherapy following conservative surgery for invasive duc...

متن کامل

Study of dosimetric and spatial variations due to applicator positioning during inter-fraction high-dose rate brachytherapy in the treatment of carcinoma of the cervix: A three dimensional dosimetric analysis

Background: This study evaluates dosimetric and spatial variations in inter–fraction applicator positioning in high dose rate (HDR) brachytherapy. Materials and Methods: This study includes 25 retrospective patients of carcinoma of the cervix. Each patient received 5 fractions of HDR intracavitary brachytherapy. High Risk-Clinical Target Volume (HR-CTV) were drawn on CT images. First impl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation Oncology (London, England)

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2007