A physiology simulator: validation of its respiratory components and its ability to predict the patient's response to changes in mechanical ventilation.

نویسندگان

  • J G Hardman
  • N M Bedforth
  • A B Ahmed
  • R P Mahajan
  • A R Aitkenhead
چکیده

We aimed to validate the mathematical validity and accuracy of the respiratory components of the Nottingham Physiology Simulator (NPS), a computer simulation of physiological models. Subsequently, we aimed to assess the accuracy of the NPS in predicting the effects of a change in mechanical ventilation on patient arterial blood-gas tensions. The NPS was supplied with the following measured or calculated values from patients receiving intensive therapy: pulmonary shunt and physiological deadspace fractions, oxygen consumption, respiratory quotient, cardiac output, inspired oxygen fraction, expired minute volume, haemoglobin concentration, temperature and arterial base excess. Values calculated by the NPS for arterial oxygen tension and saturation (PaO2 and SaO2), mixed venous oxygen tension and saturation (PvO2 and SvO2), arterial and mixed venous carbon dioxide tension (PaCO2 and PvCO2) and arterial pH were accurate compared with measured values. Subsequently, arterial gas responses to changes in minute volume of FiO2 were measured in 31 patients and were compared with the NPS prediction for each response. The 95% limits of agreement in predicting the magnitude of change were: arterial oxygen tension -2.07 to 2.47 kPa; PaCO2 -0.33 to 0.67 kPa; and pH -0.023 to 0.033. This investigation has validated respiratory components of the NPS. We recommend the NPS as a clinical tool for predicting the effects of alterations in mechanical ventilation in stable patients in the intensive care unit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventilator with a capnograph smart sensors

Today, the world has witnessed increasing development in various fields, including industry and medicine. One of the best ways to achieve these objectives is the integration of different sciences including electronics, robotics and medicine. Ventilator set that provides respiratory function for patients get smarter and more capable than older generations, during mechanical ventilation to preven...

متن کامل

Comparison of Fentanyl and Midazolam for the Sedation of Infants Under Mechanical Ventilation; A Randomized Clinical Trial

Background: Neonatal respiratory distress syndrome (NRDS), a life-threatening pulmonary disorder, involves 1% of all deliveries worldwide. Shallow breathing causes restlessness in infants, which itself affects pulmonary function; thus, sedative medications are used to preserve better pulmonary function. There are different opinions about the benefits and superiority of these dr...

متن کامل

بررسی عوارض ریوی ناشی از تهویه مکانیکی در نوزادان بستری در بخش NICU

Introduction & Objective: The main indication of mechanical ventilation is in the treatment of neonates with respiratory failure. With the increased use of mechanical ventilation, its complications have increased too. The aim of this study was to evaluate the prevalence of complications and short-term improvement in infants undergoing mechanical ventilation in the neonatal intensive care unit (...

متن کامل

Large Lithium Polymer Battery Modeling for the Simulation of Hybrid Electric Vehicles Using the Equivalent Circuit Method

In the present study, a model of a large Lithium Polymer (Li-Po) battery for use in the simulation of Hybrid Electric Vehicles (HEVs) is developed. To attain this goal, an Equivalent Circuit (EC) consisting of a series resistor and two RC parallel networks is considered. The accuracy and the response time of the model for use in an HEV simulator are studied. The battery parameters identifica...

متن کامل

The Effect of Intravenous Tocilizumab Therapy on the Prognosis of Patients with Covid-19: A Case-control Study

Background and Objective: Tocilizumab is a monoclonal antibody against the Interleukin-6 (IL6) receptor, but its effect on improving the clinical condition of coronavirus disease of 2019 (COVID-19) patients is debated. Accordingly, this study investigated the impact of Tocilizumab as an alternative treatment on the outcomes of covid-19 patients. Methods: In this retrospective case-control stud...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 81 3  شماره 

صفحات  -

تاریخ انتشار 1998