A Rapid, Multiplexed, High-Throughput Flow-Through Membrane Immunoassay: A Convenient Alternative to ELISA

نویسندگان

  • Sujatha Ramachandran
  • Mitra Singhal
  • Katherine G. McKenzie
  • Jennifer L. Osborn
  • Amit Arjyal
  • Sabina Dongol
  • Stephen G. Baker
  • Buddha Basnyat
  • Jeremy Farrar
  • Christiane Dolecek
  • Gonzalo J. Domingo
  • Paul Yager
  • Barry Lutz
چکیده

This paper describes a rapid, high-throughput flow-through membrane immunoassay (FMIA) platform. A nitrocellulose membrane was spotted in an array format with multiple capture and control reagents for each sample detection area, and assay steps were carried out by sequential aspiration of sample and reagents through each detection area using a 96-well vacuum manifold. The FMIA provides an alternate assay format with several advantages over ELISA. The high surface area of the membrane permits high label concentration using gold labels, and the small pores and vacuum control provide rapid diffusion to reduce total assay time to ~30 min. All reagents used in the FMIA are compatible with dry storage without refrigeration. The results appear as colored spots on the membrane that can be quantified using a flatbed scanner. We demonstrate the platform for detection of IgM specific to lipopolysaccharides (LPS) derived from Salmonella Typhi. The FMIA format provides analytical results comparable to ELISA in less time, provides integrated assay controls, and allows compensation for specimen-to-specimen variability in background, which is a particular challenge for IgM assays.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiplexed immunoassays by flow cytometry for detection of clenbuterol, chloramphenicol and sulfadimidine with high sensitivity and selectivity

An accurate, rapid and cost-effective detection on the environmental hazardous chemicals is the cornerstone of efficient food safe management. Here we discuss the relevance of an emerging technology, multiplexed competitive immunoassays read by flow cytometry, for the detection of Clenbuterol, Chloramphenicol and sulfadimidine. In these assays, multiple fluorescent microspheres, conjugated to d...

متن کامل

Multiplexed Immunoassays

Immunoassay has been widely used for quantification of proteins and small molecules in medical diagnostics, proteomics, drug discovery, and various biological research.1 ELISA (Enzyme-Linked ImmunoSorbant Assay) is the most commonly used immunoassay format.2 Traditional ELISA assays used in clinical settings are laborious and expensive and often consume large quantities of reagents and patient ...

متن کامل

Targeting Colorectal Cancer Cell Lines Using Nanobodies; AgSK1as a Potential Target

Background: Colorectal cancer is the third most common type of aggressive cancers. Chemotherapy, surgery,and radiotherapy are the common therapeutic options for treating this cancer. Due to the adverse side-eff ects of these methods, immunotherapy is considered as an appropriate alternative therapeutic option. Treatment through the application of monoclonal antibodies is considered as a n...

متن کامل

Optimization of Rolling-Circle Amplified Protein Microarrays for Multiplexed Protein Profiling

Protein microarray-based approaches are increasingly being used in research and clinical applications to either profile the expression of proteins or screen molecular interactions. The development of high-throughput, sensitive, convenient, and cost-effective formats for detecting proteins is a necessity for the effective advancement of understanding disease processes. In this paper, we describe...

متن کامل

Rapid, automated, parallel quantitative immunoassays using highly integrated microfluidics and AlphaLISA

Immunoassays represent one of the most popular analytical methods for detection and quantification of biomolecules. However, conventional immunoassays such as ELISA and flow cytometry, even though providing high sensitivity and specificity and multiplexing capability, can be labor-intensive and prone to human error, making them unsuitable for standardized clinical diagnoses. Using a commerciali...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2013