Deformable template models for emission tomography

نویسندگان

  • Yali Amit
  • Kevin M. Manbeck
چکیده

The reconstruction of emission tomography data is an ill-posed inverse problem and, as such, requires some form of regularization. Previous efforts to regularize the restoration process have incorporated rather general assumptions about the isotope distribution within a patient's body. A theoretical and algorithmic framework is presented in which the notion of a deformable template can be used to identify and quantify brain tumors in pediatric patients. Patient data and computer simulation experiments are presented which illustrate the performance of the deformable template approach to single photon emission computed tomography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Global optimization-based deformable meshes for surface extraction from medical images

This thesis deals with surface extraction from noisy volumetric images, which is a common problem in medical image analysis. Due to noise, the use of a-priori information about surface topology and shape is necessary for automatic surface extraction methods. Deformable surface models can incorporate such geometric knowledge into extraction process which is restated as an energy minimization pro...

متن کامل

Delineation of drain Structures from Positron Emission Tomography Images with Deformable Models

Segmentation of positron emission tomography (PET) images is a difficult task. In this study, we propose a new method for delineation of brain structures according to the tracer uptake. The method is based on a new deformable model which is particularly designed for extracting surfaces automatically from noisy images. The automation is achieved by using a global optimization algorithm for minim...

متن کامل

Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study

Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...

متن کامل

Automatic extraction of brain surface and mid-sagittal plane from PET images applying deformable models

In this study, we propose and evaluate new methods for automatic extraction of the brain surface and the mid-sagittal plane from functional positron emission tomography (PET) images. Designing methods for these segmentation tasks is challenging because the spatial distribution of intensity values in a PET image depends on the applied radiopharmaceutical and the contrast to noise ratio in a PET ...

متن کامل

Real-Time Simulation of 4D Lung Tumor Radiotherapy Using a Breathing Model

In this paper, we present a real-time simulation and visualization framework that models a deformable surface lung model with tumor, simulates the tumor motion and predicts the amount of radiation doses that would be deposited in the moving lung tumor during the actual delivery of radiation. The model takes as input a subject-specific 4D Computed Tomography (4D CT) of lungs and computes a defor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • IEEE transactions on medical imaging

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 1993