The utility of computed tomographic angiography in a neonate on extracorporeal membrane oxygenation with extreme cyanosis after Blalock–Taussig shunt

نویسندگان

  • Jess D Rames
  • Minoo N Kavarana
  • U Joseph Schoepf
  • Anthony Marcus Hlavacek
چکیده

A modified Blalock-Taussig shunt (mBTS) is often employed to provide pulmonary blood flow in neonates that are born with cyanotic congenital heart defects. However, acute shunt thrombosis can occur in the postoperative period, resulting in profound cyanosis. In this case report, we describe the utility of computed tomographic angiography (CTA) in the management of a neonate with extreme cyanosis after placement of a mBTS while on extracorporeal membrane oxygenation. Using CTA, several small clots were identified in the shunt as well as stenosis of the left pulmonary artery; neither of which were identified with echocardiography. The CTA allowed for quick identification of the disorder and helped direct prompt surgical intervention.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blalock - Taussig shunt . modified ( polytetrafluoroethylene ) Balloon dilatation of a stenosed

A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence ofproximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months la...

متن کامل

Balloon dilatation of a stenosed modified (polytetrafluoroethylene) Blalock-Taussig shunt.

A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence of proximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months l...

متن کامل

Cardiopulmonary bypass using argatroban as an anticoagulant for a 6.0-kg pediatric patient.

A patient was born with transposition of the great arteries, double-outlet right ventricle, interrupted aortic arch, and a ventricular septal defect and underwent a Damus-Kaye-Stansel procedure with a modified Blalock-Taussig shunt at 14 days old. Three months later, this patient presented with hypoxia and bradycardia was found to have a thrombus present in the main pulmonary artery extending t...

متن کامل

Modified Blalock-taussig Shunt ----in- Hospital Shunt Occlusion: Experience at Nicvd

A modified Blalock-Taussig shunt (mBTS) is a surgically placed graft between the systemic and pulmonary arterial circulations that redirects systemic blood flow into the pulmonary circulation. It is often placed in those with rightsided obstructive cardiac defects to increase pulmonary blood flow. Postoperative shunt patency is critical to adequate systemic oxygenation. Nevertheless, in the imm...

متن کامل

Successful Repair of Critical Tricuspid Regurgitation Secondary to a Ruptured Papillary Muscle in a Neonate

Severe tricuspid regurgitation resulting from a flail leaflet is a rare cause of neonatal cyanosis. We report a neonate with profound cyanosis and severe tricuspid regurgitation caused by a rupture of the papillary muscle supporting the anterior leaflet, without other structural heart defects. Ductal patency could not be established. The repair of the tricuspid valve was performed after initial...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2017