Biomechanical comparison of interfragmentary compression in transverse fractures of the olecranon.

نویسندگان

  • J Wilson
  • A Bajwa
  • V Kamath
  • A Rangan
چکیده

Compression and absolute stability are important in the management of intra-articular fractures. We compared tension band wiring with plate fixation for the treatment of fractures of the olecranon by measuring compression within the fracture. Identical transverse fractures were created in models of the ulna. Tension band wires were applied to ten fractures and ten were fixed with Acumed plates. Compression was measured using a Tekscan force transducer within the fracture gap. Dynamic testing was carried out by reproducing cyclical contraction of the triceps of 20 N and of the brachialis of 10 N. Both methods were tested on each sample. Paired t-tests compared overall compression and compression at the articular side of the fracture. The mean compression for plating was 819 N (sd 602, 95% confidence interval (CI)) and for tension band wiring was 77 N (sd 19, 95% CI) (p = 0.039). The mean compression on the articular side of the fracture for plating was 343 N (sd 276, 95% CI) and for tension band wiring was 1 N (sd 2, 95% CI) (p = 0.038). During simulated movements, the mean compression was reduced in both groups, with tension band wiring at -14 N (sd 7) and for plating -173 N (sd 32). No increase in compression on the articular side was detected in the tension band wiring group. Pre-contoured plates provide significantly greater compression than tension bands in the treatment of transverse fractures of the olecranon, both over the whole fracture and specifically at the articular side of the fracture. In tension band wiring the overall compression was reduced and articular compression remained negligible during simulated contraction of the triceps, challenging the tension band principle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fixation of olecranon fractures and osteotomies using compression screws: a simple solution to a common problem. A study of cases.

Olecranon fractures are common skeletal injuries accounting for approximately 10% of upper extremity fractures in adults. Simple non-comminuted fractures are traditionally fixed using the tension band wiring technique. This technique, however, has several complications, most commonly prominence of the metalwork frequently requiring surgery for removal. We describe a retrospective review of a ne...

متن کامل

Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques: A CONSORT-Compliant Article: Erratum.

[In the article "Biomechanical Evaluation of Interfragmentary Compression At Tibia Plateau Fractures In Vitro Using Different Fixation Techniques: A CONSORT-compliant" article, which appeared in Volume 94, Issue 1 of Medicine, a line denoting dual authorship was omitted. K. Kojima and B. Gueorguiev contributed equally to the article.].

متن کامل

Biomechanical analysis of tension band wiring (TBW) of transverse fractures of patella

PURPOSE Tension band wiring is commonly used for fixation of simple transverse fractures. The popular configuration is parallel Kirschner wires (K-wires) and a stainless steel wire loop placed in a vertically oriented figure-of-8. METHODS We used a wooden model of a patella with a midway transverse fracture and compared four different types of fixation. The first construct had a vertical figu...

متن کامل

A biomechanical study of conventional acetabular internal fracture fixation versus locking plate fixation.

BACKGROUND Conventional internal fixation entails the use of an interfragmentary lag screw along with a plate. Not all acetabular fractures are amenable to the placement of an interfragmentary lag screw, and the fracture may be displaced during tightening of the interfragmentary lag screw. Locking plates are a possible solution. We sought to determine whether a locking plate construct can provi...

متن کامل

A biomechanical study comparing the compressive forces generated by a conventional 4.5 AO/ASIF cortical lag screw with a differentially pitched cortical compression screw.

The aim of this study was to compare the interfragmentary compression generated across a simulated femoral fracture model by a conventional 4.5 mm AO/ASIF cortical lag screw with a differentially pitched cortical compression screw. A 45-degree osteotomy was made in a whole bone composite femoral shaft, this was internally fixed with either a conventional 4.5 mm AO/ASIF cortical lag screw or the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 93 2  شماره 

صفحات  -

تاریخ انتشار 2011