Repeatability Using Automatic Tracing with Canon OCT- HS100 and Zeiss Cirrus HD-OCT 5000

نویسندگان

  • Rune Brautaset
  • Ulrika Birkeldh
  • Petra Frehr Alstig
  • Petra Wikén
  • Maria Nilsson
  • Daniel L Rubin
چکیده

BACKGROUND Optical coherence tomography (OCT), can be used in clinical practice to provide high resolution cross-sectional images of the retina, optic disc and macula structure. These measurements can be useful for early detection, diagnosis, monitoring and treatment guidance for retinal diseases. Therefore, repeatability of measurements in OCT is of great importance. METHODS Macula and optic disc parameters from the right eye of 30 healthy subjects were obtained twice with the Canon OCT-HS100 and Zeiss Cirrus HD-OCT 5000. Repeatability was evaluated by use of the coefficient of repeatability (CR) and the coefficient of repeatability as a percentage of the mean (CR%), and the obtained measurements were compared between the instruments. RESULTS CR% of optic disc parameters ranged between 0.90 and 22.22% and 0.00 and 16.00% with the Canon and Zeiss OCT respectively. For macular parameters CR% ranged between 0.62 and 2.81% and 0.99 and 1.81% with the Canon and Zeiss OCT respectively. No statistical difference could be found when comparing the CR of all macular and disc measurements between the instruments. Compared to our previously published data repeatability has significantly improved with the inclusion of automatic tracking systems with both the Canon and Zeiss OCT. CONCLUSION Automatic tracking function improves repeatability in both Canon OCT-HS100 and Zeiss Cirrus HD-OCT 5000. However, measurements generated by the two instruments are still not interchangeable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reproducibility of macular thickness measurements using Cirrus SD-OCT in neovascular age-related macular degeneration.

PURPOSE To assess the test-retest variability of central and sectorial macular thickness measurements obtained by Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA) in neovascular age-related macular degeneration (nAMD). METHODS Macular thickness measurements of nine standard ETDRS subfields were obtained and analyzed. The repeatability of macular thickness measurements by Cirrus HD-OCT was asses...

متن کامل

Repeatability of Perimacular Ganglion Cell Complex Analysis with Spectral-Domain Optical Coherence Tomography

Purpose. To assess the repeatability of spectral-domain optical coherence tomography to measure macular and perimacular ganglion cell complex thicknesses and compare retinal ganglion cell parameters between algorithms. Methods. Ninety-two nonglaucomatous eyes from 92 participants underwent macular and perimacular ganglion cell complex thickness measurement using OCT-HS100 Glaucoma 3D algorithm ...

متن کامل

Repeatability of optic nerve head parameters measured by spectral-domain OCT in healthy eyes.

BACKGROUND AND OBJECTIVE To evaluate the repeatability of optic nerve head (ONH) measurements by spectral-domain optical coherence tomography. PATIENTS AND METHODS Three scans were acquired in 32 healthy subjects during one session. Using Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA), the cup-to-disc ratio (CDR), disc area, rim area, cup volume, and horizontal and vertical CDRs were investig...

متن کامل

Macular thickness measurements in healthy eyes using six different optical coherence tomography instruments.

PURPOSE To compare central retinal thickness (CRT) measurements in healthy eyes by different commercially available OCT instruments and to compare the intersession reproducibility of such measurements. METHODS Six different OCT instruments (Stratus OCT [Carl Zeiss Meditec, Inc. Dublin, CA], SOCT Copernicus [Reichert/Optopol Technology, Inc., Depew, NY], Spectral OCT/SLO [Opko/OTI, Inc., Miami...

متن کامل

Central retinal thickness measured with HD-OCT shows a weak correlation with visual acuity in eyes with CSME.

AIMS To investigate the correlation between increased retinal thickness (RT) measured with spectral domain high-definition optical coherence tomography (OCT) (Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, California, USA)) and best-corrected visual acuity (BCVA) in eyes with clinically significant macular oedema (CSME) and type 2 diabetes. METHODS Seventy eyes with CSME were included in this obs...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016