Aortic prosthetic ring annuloplasty: a useful adjunct to a standardized aortic valve-sparing procedure?

نویسندگان

  • Emmanuel Lansac
  • Isabelle Di Centa
  • Nicolas Bonnet
  • Pascal Leprince
  • Akthar Rama
  • Christophe Acar
  • Alain Pavie
  • Iradj Gandjbakhch
چکیده

OBJECTIVE Dilation of aortic annulus, sinuses of Valsalva, and sinotubular junction (STJ) diameters are the characteristic lesions of aortic root aneurysm. The remodeling technique reduces STJ diameter and creates three neosinuses of Valsalva. Alternatively, the reimplantation technique reduces both annulus and STJ diameters to the detriment of aortic root dynamics. Although the remodeling technique is recognized as the most physiological valve-sparing procedure, aortic annulus dilation may jeopardize its results. A standardized approach that combines an external subvalvular aortic prosthetic ring annuloplasty with the remodeling technique is suggested. METHODS Eighty-three patients underwent an elective aortic root remodeling procedure, either isolated (group 1, n=34) or combined with an external subvalvular aortic prosthetic ring annuloplasty (group 2, n=49). Preoperative aortic regurgitation was 1.59+/-1.1 (group 1) and 1.97+/-1.3 (group 2) (NS). The aortic annulus was more dilated in group 2 than in group 1 (27+/-2.77 mm vs 26.4+/-2.3 mm, p<0.01). Residual aortic regurgitation > or =grade II was the conversion criteria for aortic valve replacement. RESULTS Operative mortality was 3.6% (n=3). Intraoperative conversion for valve replacement was 32.7% in group 1 (n=11) versus 4.2% in group 2 (n=2) (p<0.001). In group 1, preoperative annulus diameter was larger for converted than for valve-spared patients (27.6+/-1.7 mm vs 25.2+/-1.5 mm, p<0.02). In group 2, implanted aortic ring significantly reduced annulus diameter (20.6+/-1.8 mm) without significant aortic valve gradient (8.3+/-3 mmHg). Follow-up was 17.2+/-13.4 months (group 1) and 10.41+/-7.95 months (group 2). Reoperation for recurrent aortic regurgitation was 13% in group 1 (n=3) versus 4.2% in group 2 (n=2). Echocardiographic follow-up found residual aortic regurgitation < or =grade I in 17 patients in group 1 (90%) versus 43 patients in group 2 (95.5%) and of grade II in two patients in group 1 (10%) and two patients in group 2 (4.5%). CONCLUSION The addition of external aortic prosthetic ring annuloplasty improves the remodeling technique's operative reproducibility and short-term results. Therefore, its use as a systematical adjunct to the remodeling procedure is suggested. However, further long-term evaluation comparing this valve-sparing procedure to composite graft replacement should define the best surgical strategy for aortic root aneurysm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Valve sparing root replacement: the remodeling technique with external ring annuloplasty.

A standardized approach to aortic valve repair is described associating a physiological remodeling of the root, with resuspension of cusp effective height and a subvalvular aortic annuloplasty using an external expansible ring. This device achieves a complete calibrated annuloplasty, in order to increase cups coaptation height and protect the repair. This is a video-atlas describing the surgica...

متن کامل

مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی

In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...

متن کامل

Early results of a novel technique for ring-reinforced aortic valve and root restoration.

OBJECTIVES Surgery for aortic root aneurysm without valve stenosis is increasingly being transformed from the Bentall procedure to valve-sparing aortic root remodelling or reimplantation. In this report, a new repair option is explored, with full functional 'restoration' of the aortic root complex using a geometric annuloplasty ring, leaflet repair, and sinus/ascending aortic replacement with a...

متن کامل

Valve sparing surgery in an adult patient with dextrocardia and annuloaortic ectasia

We report the case of a patient with situs inversus totalis, annuloaortic ectasia complicated by aortic insufficiency and mitral regurgitation which induced congestive heart failure. Both valvular lesions were repaired physiologically using aortic root sparing Yacoub 'remodeling' technique and mitral ring annuloplasty. Valve sparing techniques can be used effectively even in patients with compl...

متن کامل

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 2006