Quartz crystal microbalance based on torsional piezoelectric resonators.

نویسندگان

  • W Bücking
  • B Du
  • A Turshatov
  • A M König
  • I Reviakine
  • B Bode
  • D Johannsmann
چکیده

A quartz crystal microbalance (QCM) is described, which is based on a torsional resonator, rather than a conventional thickness-shear resonator. Typical applications are measurements of film thickness in the coating industry and monitoring of biofouling. The torsional QCM is about a factor of 100 less sensitive than the conventional QCM. On the other hand, it can probe film thicknesses in the range of hundreds of microns, which is impossible with the conventional QCM due to viscoelastic artifacts. Data acquisition and data analysis proceed in analogy to the conventional QCM. An indicator of the material's softness can be extracted from the bandwidth of the resonance. Within the small-load approximation, the frequency shift is independent of whether the sample is applied to the face or to the side of the cylinder. Details of the geometry matter if the viscoelastic properties of the sample are of interest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CMOS-Integrated Film Bulk Acoustic Resonators for Label-Free Biosensing

The throughput is an important parameter for label-free biosensors. Acoustic resonators like the quartz crystal microbalance have a low throughput because the number of sensors which can be used at the same time is limited. Here we present an array of 64 CMOS-integrated film bulk acoustic resonators. We compare the performance with surface plasmon resonance and the quartz crystal microbalance a...

متن کامل

Quartz Crystal Microbalance Study of Dna Immobilization and Hybridization for Dna Sensor Development

Piezoelectric materials such as quartz can be used to detect mass change due to their piezoelectric properties. Quartz Crystal Microbalance (QCM) is an extremely sensitive mass sen frequency biosensor mass mea for QCM DNA biosensor was developed. The potential for QCM to be employed as immunosensor sor, capable of measuring sub-nanogram levels by detecting change in the of a quartz crystal reso...

متن کامل

Improvement of Sensor Sensitivity of Quartz Crystal Microbalance by Mechanical and Chemical Treatment∗

The influence of quartz plate roughening on the dynamic parameters of quartz resonators has been studied. For this aim AT-cut quartz plates with a diameter of 8 mm, after a standard technological cleaning, are subjected to treatment with abrasive of varying grain sizes: 3, 7, 14 and 20 μm. Piezoquartz resonators are fabricated on these plates with 4 mm Au electrodes. The alterations of resonato...

متن کامل

Shear Mode Piezoelectric Thin Film Resonators

1.1 Shear mode bulk acoustic wave devices and sensors Acoustic microsensor technique, well known as QCM (Quartz crystal microbalance) or TSM (Thickness shear mode) sensor, is an effective method to detect small mass loading on the sensor surface. This sensor can be operated even in liquid by using shear mode resonance. Therefore, shear mode piezoelectric film resonators are attractive for liqui...

متن کامل

Development of a Flow Injection Based High Frequency Dual Channel Quartz Crystal Microbalance

When the quartz crystal microbalance (QCM) is used in liquid for adsorption or desorption monitoring based bio- or chemical sensing applications, the frequency shift is not only determined by the surface mass change, but also by the change of liquid characteristics, such as density and viscosity, which are greatly affected by the liquid environmental temperature. A monolithic dual-channel QCM i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 78 7  شماره 

صفحات  -

تاریخ انتشار 2007