Performance Comparison of High-Speed Dual-Pneumatic Vitrectomy Cutters during Simulated Vitrectomy with Balanced Salt Solution.

نویسندگان

  • Dina Joy K Abulon
  • David C Buboltz
چکیده

PURPOSE To measure flow rate of balanced salt solution and IOP during simulated vitrectomy using two sets of high-speed dual-pneumatic probes. METHODS A closed-model eye system measured IOP and flow rate of a balanced salt solution through infusion cannula. The Constellation Vision System was tested with two sets of high-speed dual-pneumatic probes (UltraVit 23-gauge and enhanced 25+-gauge 5000-cpm probes; UltraVit 23-gauge and enhanced 25+-gauge 7500-cpm probes; n = 6 each) under different vacuum levels and cut rates in three duty cycle modes. RESULTS In both probe sets, flow rates were dependent on cut rate with the biased open and biased closed duty cycles. Flow rates were highest with the biased open duty cycle, lower with the 50/50 duty cycle, and lowest with the biased closed duty cycle. IOP, as expected, was inversely associated with flow rate using both probe sets. CONCLUSIONS The 7500-cpm probes offer greater control and customization compared with 5000-cpm probes under certain experimental conditions. At maximum cut rates, performance of 7500-cpm probes was similar to that of 5000-cpm probes, suggesting that 7500-cpm probes may be used without sacrifice of flow rate and IOP stability. TRANSLATIONAL RELEVANCE Customization of vitrectomy parameters allows greater surgeon control during vitrectomy and may expand the usefulness of vitrectomy probes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vitreous flow rates through dual pneumatic cutters: effects of duty cycle and cut rate

PURPOSE We aimed to investigate effects of instrument settings on porcine vitreous flow rates through dual pneumatic high-speed vitrectomy probes. METHODS The CONSTELLATION(®) Vision System was tested with 250, 450, and 650 mmHg of vacuum using six ULTRAVIT(®) vitrectomy probes of each diameter (25+(®), 25, 23, and 20 gauge) operated from 500 cuts per minute (cpm) up to 5,000 cpm. Duty cycle ...

متن کامل

Fluidics in a dual pneumatic ultra high-speed vitreous cutter system.

BACKGROUND Dual pneumatic systems use two separate air line tubes to open and close the cutter and can achieve high cut rates. The purpose of this study is to evaluate the influence of gauge size, cut rate and aspiration on the flow rate performance of ultra high-speed cutters operated with a commercially available dual pneumatic vitrectomy system. METHODS Analysis of a high-speed video was u...

متن کامل

Porcine Vitreous Flow Behavior During High-Speed Vitrectomy up to 7500 Cuts per Minute

PURPOSE To evaluate the impact of high-speed cut rates (up to 7500 cuts per minute [cpm]) on vitreous flow through various gauge probes. METHODS An open-sky vitrectomy technique was performed on porcine eyes using the CONSTELLATION Vision System with three different gauges of dual-pneumatic probes (27+-, 25+-, and 23-gauge UltraVit probes; n = 5 for each gauge). Flow rate was calculated by La...

متن کامل

Performance characteristics of a straight versus bent 25-gauge vitrector.

BACKGROUND AND OBJECTIVE During vitrectomy in phakic patients, lens damage can occur while shaving the peripheral vitreous. Modifying the vitrector with a slight bend can diminish this risk. MATERIALS AND METHODS To assess whether the bent vitrector performs to standard, the cutting and aspiration functionality of a straight and bent cutter was tested on both the vitreous from an enucleated p...

متن کامل

A Simple Method for Removal of Particles from the Retinal Surface during Vitrectomy

Removal of particulate materials from the retinal surface is somewhat difficult during small gauge vitrectomy. Simple injection of balanced salt solution into the vitreous cavity in a controlled manner using a connector tubing between the syringe and needle can produce enough turbulence to float the deposited material and remove it.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Translational vision science & technology

دوره 4 1  شماره 

صفحات  -

تاریخ انتشار 2015