Prognostic value of office and ambulatory blood pressure measurements in pregnancy.

نویسندگان

  • Ramón C Hermida
  • Diana E Ayala
چکیده

With the objective to assess the prognostic value of office values as compared with ambulatory monitoring in pregnancy, we analyzed 2430 blood pressure series systematically sampled from 403 untreated pregnant women for 48 consecutive hours every 4 weeks from the first visit to the hospital until delivery. Women were divided into 5 groups: "detected" gestational hypertension, women with office blood pressures >140/90 mm Hg after 20 weeks of gestation and hyperbaric index (area of blood pressure excess above the upper limit of a time-specified tolerance interval) consistently above the threshold for diagnosing hypertension in pregnancy; "undetected" gestational hypertension, office values <140/90 mm Hg but hyperbaric index above the threshold for diagnosis; normotension, both office values and hyperbaric index below the thresholds for diagnosis; white coat hypertension, women with recorded diagnosis of gestational hypertension but hyperbaric index consistently below the threshold for diagnosis; and preeclampsia, defined as gestational hypertension and proteinuria. Results indicate small and nonsignificant differences in 24-hour mean of ambulatory pressures between "detected" and "undetected" gestational hypertension at all stages of pregnancy, in contrast with highly significant differences between these two groups and normotensive pregnancies. Average office blood pressure values were similar for preeclampsia, "detected," and "undetected" gestational hypertension. The hyperbaric index was, however, significantly higher for women with preeclampsia after 20 weeks of gestation as compared with all other groups and higher for women with either "detected" or "undetected" gestational hypertension as compared with normotensive pregnant women. The incidence of preterm delivery and intrauterine growth retardation were similar for "detected" and "undetected" gestational hypertension but significantly lower for normotensive women. In pregnancy, the hyperbaric index derived from ambulatory monitoring is markedly superior to office measurements for diagnosis of what should be truly considered gestational hypertension, as well as for prediction of the outcome of pregnancy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Letter regarding article by Sega et al, "Prognostic value of ambulatory and home blood pressures compared with office blood pressure in the general population".

“Prognostic Value of Ambulatory and Home Blood Pressures Compared With Office Blood Pressure in the General Population” To the Editor: We read with interest the paper by Sega et al regarding the prognostic value of ambulatory, home, and office blood pressure in the PAMELA population.1 However, we find that the main conclusions of the report may be driven by the lack of adjustment for confounder...

متن کامل

Blood Pressure Measurements Taken by Patients are Similar to Home and Ambulatory Blood Pressure Measurements

OBJECTIVE To compare blood pressure measurements taken at home by physicians, nurses, and patients with office blood pressure measurement , ambulatory blood pressure monitoring and home blood pressure measurement. METHODS A total of 44 patients seen by a home care program were studied. Protocol 1 a) blood pressure was measured by the patient, a physician and a nurse during a regular home visi...

متن کامل

Office versus ambulatory recordings of blood

The long-term prognostic value of ambulatory blood pressure recordings in essential hypertension is poorly documented. A European Multicenter study has been set up to evaluate office versus ambulatory (OVA) recordings during a follow-up period of 5 years in a minimum of 2000 patients. The end-point of the study is the question of whether ambulatory blood pressure measurements are better correla...

متن کامل

Sleep-time blood pressure and the prognostic value of isolated-office and masked hypertension.

BACKGROUND Elevated sleep-time blood pressure (BP) is a better predictor of cardiovascular risk than the awake or 24 h BP means. However, discrepancies in the diagnosis of hypertension between clinic and ambulatory measurements (isolated-office and masked hypertension) are frequently defined by comparing clinic with only awake BP. We evaluated the impact of sleep-time BP in the prognostic value...

متن کامل

Long-term prognostic value of white coat hypertension: an insight from diagnostic use of both ambulatory and home blood pressure measurements.

The prognostic value of white coat hypertension (WCH) is still debated. In 2051 subjects representative of the general population of Monza, we measured office, ambulatory, and home blood pressure (BP). The risk of cardiovascular and all-cause mortality was assessed over 16 years in normotensive, sustained hypertensive, and WCH subjects, the last group being defined as usually done in clinical p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 2002