Trace element removal during in vitro and in vivo continuous haemodialysis.
نویسندگان
چکیده
BACKGROUND Continuous renal replacement therapy (CRRT) increasingly is being used to treat critically ill patients with renal disease. CRRT removes waste products but also nutrients. Our understanding of trace element CRRT clearance has been limited by poor assay sensitivity. The development of inductively coupled plasma mass spectrometry (ICP-MS) allows for the measurement of CRRT trace element removal. METHODS Continuous venovenous haemodialysis (CVVHD) transmembrane clearances of trace elements and urea were assessed using a bovine blood-based in vitro model using two different haemodialyser types. These findings were validated in 10 critically ill adult patients receiving continuous venovenous haemodiafiltration (CVVHDF). Calculated daily trace element loss was compared with a typical dose of daily trace element supplementation. RESULTS The mean +/- SD in vitro CVVHD transmembrane clearances (ml/min) for the polysulfone haemodialyser were chromium 0.97 +/- 0.23, copper 0.47 +/- 0.18, manganese 4.6 +/- 3.6, selenium 1.2 +/- 0.63 and zinc 2.3 +/- 0.32 and for the cellulose diacetate haemodialyser chromium 1.54 +/- 0.91, copper 0.21 +/- 0.07, manganese 7.8 +/- 4.1, selenium 0.76 +/- 0.39 and zinc 2.7 +/- 0.37. The in vivo CVVHDF transmembrane clearances (ml/min) were chromium 5.4 +/- 2.4, copper 0.45 +/- 0.33, manganese 1.9 +/- 4.6, selenium 1.6 +/- 1.2, and zinc 4.0 +/- 1.3. CONCLUSION ICP-MS assays detected the five trace elements in the effluent of CVVHDF patients. Trace element CVVHD transmembrane clearance estimates for our in vitro model were supported by the in vivo CVVHDF findings. Calculated daily trace element loss attributed to CVVHD and CVVHDF with dialysate flow rates of 33.3 ml/min is less than what is provided in a daily dose of a trace element supplementation product.
منابع مشابه
The influence of a slow-release multi-trace element ruminal bolus on trace element status, number of ovarian follicles and pregnancy outcomes in synchronized Afshari ewes
Published data on the effects of ruminal bolus on the number of ovulatory follicles in ewes does not exist. The present study determined the effects of a ruminal bolus on trace element status, follicular dynamics and reproductive performance in ewes. Eighty Afshari cycling ewes were synchronized during breeding season using CIDR for 14 days and assigned to 4 groups (n=20); group 1 received a si...
متن کاملA continuous in vitro method for estimation of the bioavailability of minerals and trace elements in foods: application to breads varying in phytic acid content.
A continuous in vitro method for the estimation of the bioavailability of minerals and trace elements is presented. This in vitro method is believed to be more representative of in vivo physiological conditions than in vitro methods based on equilibrium dialysis, because dialysable components are continuously removed from the pancreatic digestion mixture. The continuous in vitro method is compa...
متن کاملA comparison of the clearance of urographic contrast medium (sodium diatrizoate) by peritoneal and haemodialysis.
1. The clearance of isotopically labelled sodium diatrizoate by haemodialysis was measured in vitro, with simulated extracellular fluid, and in vivo in eleven patients, at varying rates of fluid or plasma flow. Clearance was also measured in five patients undergoing peritoneal dialysis. In all instances simultaneous measurements of urea clearance were made and the diatrizoate/urea clearance rat...
متن کاملEffects of statistical distribution of joint trace length on the stability of tunnel excavated in jointed rock mass
The rock masses in a construction site of underground cavern are generally not continuous, due to the presence of discontinuities, such as bedding, joints, faults, and fractures. The performance of an underground cavern is principally ruled by the mechanical behaviors of the discontinuities in the vicinity of the cavern. During underground excavation, many surrounding rock failures have close r...
متن کاملElimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry
A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 22 10 شماره
صفحات -
تاریخ انتشار 2007