Blocking noise but not music lowers bispectral index scores during sedation in noisy operating rooms.
نویسندگان
چکیده
STUDY OBJECTIVE To determine whether playing music or blocking noise can reduce bispectral index (BIS) values during propofol sedation. DESIGN Prospective, randomized, single-blinded study. SETTING Operating room. PATIENTS 63 ASA physical status I and II patients, aged 55 to 75 years, undergoing total knee replacement. INTERVENTIONS Patients were divided into three groups: noise, silence, and music. After induction of combined spinal-epidural anesthesia, sedation was begun with 1.2 mug/mL of propofol in a target-controlled infusion. In the silence group, patients' ears were packed tightly to block ambient noise, whereas patient-selected music was applied to patients in the music group. Patients in the noise group were exposed to ambient operating room noise. MEASUREMENTS Bispectral index measurement was recorded 7 times during operation. Ambient room noise was recorded at the same time sequence. MAIN RESULTS Sound level was highest when the saw (T3, 80.25 dB) and the impact device (T4, 80.98 dB) were in use. Bispectral index scores in the silence group during those times (T3, 68.5 vs 76.9, P = 0.025, and T4, 67.6 vs 78, P = 0.005) were lower than in the noise group. However, BIS scores were similar in the noise and music groups. Preoperative anxiety level, postoperative comfort level, and pain scores were similar in all groups. CONCLUSION Blocking noise is more effective than playing music in reducing BIS scores during propofol sedation in a noisy environment.
منابع مشابه
Validation of the bispectral index monitor during conscious and deep sedation in children.
UNLABELLED In this study, we tested the validity of the bispectral index (BIS) monitor during conscious and deep sedation of children by comparing it with the University of Michigan Sedation Scale (UMSS), a validated observational pediatric sedation scale. Eighty-six children <12 yr of age were enrolled in this observational study. The subjects underwent conscious or deep sedation administered ...
متن کاملBispectral index values, sedation-agitation scores, and plasma Lorazepam concentrations in critically ill surgical patients.
BACKGROUND Publications on the use of the bispectral index for sedation monitoring in the intensive care unit are increasing. However, few studies have involved correlation of bispectral index with serum drug concentrations. OBJECTIVES To assess the degree of correlation between bispectral index values, scores on the Sedation-Agitation Scale, and steady-state serum concentrations of lorazepam...
متن کاملBispectral index monitoring during sedation with sevoflurane, midazolam, and propofol.
BACKGROUND Bispectral Index (BIS) has been used to measure sedation depth. Ideally, to guide anesthetic management, range of BIS scores at different sedation levels should not overlap, and BIS should be independent of drug used. This study assessed ability of BIS to predict sedation depth between sevoflurane, propofol, and midazolam. Quality of recovery was also compared. METHODS Patients und...
متن کاملCorrelation between Bispectral Index and Predicted Effect-site Concentration of Propofol in Different Levels of Target-Controlled, Propofol Induced Sedation in Healthy Volunteers
Introduction: Bispectral Index is an objective tool to assess electroencephalographic activity and measure the effect of certain sedatives and hypnotics on the brain. In addition, there are certain subjective tools such as the observer's assessment of alertness and sedation which are used. The correlation between BIS and the concentration of propofol in the brain, and the relationship between t...
متن کاملThe use of bispectral index monitors in paediatric intensive care
The bispectral index (BIS) is a processed neurophysiological electroencephalographic parameter that may be used to evaluate the depth of sedation in critically ill children. Triltsch and colleagues attempted to correlate BIS scores with a commonly used clinical sedation scoring system. They were able to demonstrate good correlation during deep sedation and in cases where the electrical impedanc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical anesthesia
دوره 20 1 شماره
صفحات -
تاریخ انتشار 2008