BACKGROUND The majority of spinal surgeons now utilize intraoperative neurophysiological monitoring (IONM) during spinal procedures to limit the risk of inadvertent injury. Nevertheless, probably the most frequent error is the failure of the surgeon and IONM to obtain adequate preoperative baselines (e.g. before intubation or positioning). METHODS Intraoperative neural monitoring should begin with the spinal surgeon, anesthesiologist, and monitoring technician/neurologist reviewing the patient's neurological deficits, the operative approach, the most anticipated risks and complications as well as the type of monitoring to be used (e.g. somatosensory evoked responses [SEP], motor evoked potential [MEP] monitoring, and electromyography [EMGs]). Baseline data should accurately reflect the preoperative status of the patient, and provide the appropriate data to be monitored and maintained throughout surgery. RESULTS Significant but transient changes from the established preoperative baseline SEP and MEP often reflect alterations in the anesthetic technique (e.g. hypotension/hypoperfusion). However, when these changes persist, and resuscitative maneuvers have been exhausted (e.g. removing an oversized graft to avoid ischemia, utilizing total intravenous anesthesia [TIVA] correctly, reversing hypotension, changing the patient's cervical position, checking the electrode placement, checking the position of the limbs, and other factors), significant MEP/SEP changes may signal a major impending neural injury. CONCLUSION IONM is only as good as how competently it is implemented by the technologist/neurologist, and understood by the surgeon and anesthesiologist. If any team member does not understand what and how the monitoring should be performed, then it becomes a useless adjunct to spinal surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multimodal Intraoperative Neurophysiological Monitoring in Spinal Cord Surgery.

AIM Intraoperative neurophysiological monitoring (IONM) monitors the functional integrity of critical neural structures by electrophysiological methods during surgery. Multimodality combines different neurophysiological methods to maximize diagnostic efficacy and provide a safety margin to improve the outcomes of spinal surgery. Our aim was to share our intraoperative monitoring experiences wit...

متن کامل

The value of intraoperative neurophysiological monitoring for microsurgical removal of conus medullaris lipomas: a 12-year retrospective cohort study

BACKGROUND Lipomas in the lower spinal canal can lead to progressive neurological deficits, so they may have to be surgically removed. Intraoperative neurophysiological monitoring serves to minimize the morbidity of the surgical procedure. However, so far there are no evidence-based recommendations which type of monitoring procedure or combination of procedures to choose. METHODS The aim of t...

متن کامل

Exploration of the Intraoperative Motor Evoked Potential.

STUDY DESIGN Prospective study. OBJECTIVE The objectives of the study was to (1) seek a relation between motor evoked potential (MEP) and corresponding cervical cord function in cervical compression myelopathy (CCM) and (2) explore a high-sensitive MEP range that can predict the intraoperative monitoring change ahead in cervical spine surgery. SUMMARY OF BACKGROUND DATA There have been lots...

متن کامل

Intraoperative Neurophysiological Monitoring for Spinal Cord Tumor Surgery: Comparison of Motor and Somatosensory Evoked Potentials According to Tumor Types

OBJECTIVE To identify which combination of motor evoked potentials (MEPs) and somatosensory evoked potentials (SEPs) is most reliable for postoperative motor deterioration during spinal cord tumor surgery, according to anatomical and pathologic type. METHODS MEPs and SEPs were monitored in patients who underwent spinal cord tumor surgery between November 2012 and August 2016. Muscle strength ...

متن کامل

SEP Montage Variability Comparison during Intraoperative Neurophysiologic Monitoring

Intraoperative monitoring is performed to provide real-time assessment of the neural structures that can be at risk during spinal surgery. Somatosensory evoked potentials (SEPs) are the most commonly used modality for intraoperative monitoring. SEP stability can be affected by many factors during the surgery. This study is a prospective review of SEP recordings obtained during intraoperative mo...