Automated HPLC assay of fluoxetine and norfluoxetine in serum.

نویسندگان

  • J H Nichols
  • J R Charlson
  • G M Lawson
چکیده

This automated assay determines the concentration of the antidepressant fluoxetine (Prozac) and its active metabolite norfluoxetine in serum by reversed-phase HPLC with spectrophotometric detection. Extraction, injection, and quantification are performed by the Gilson Aspec automated sample handler. The patient's specimen, with added protriptyline as internal standard, is extracted with solid-phase and liquid-liquid methods. Separation is conducted isocratically on a 5-microns (particle size) Supelcosil LC-8-DB reversed-phase column with a triethylamine acetate:acetonitrile mobile phase. The detection limit is 10 micrograms/L and absorbance varies linearly with concentration between 20 and 1,000 micrograms/L for both compounds. Mean recovery was 62% for fluoxetine and 70% for norfluoxetine over linear limits. Within-run and day-to-day imprecision (CV), evaluated at three concentrations (50, 200, and 500 micrograms/L), ranged from 2% to 7%. An extensive interference study of 108 drugs was conducted. Results (n = 58) by the automated method (y) correlated well with those by a manual HPLC method (x): y = 0.96x + 10.20 (r = 0.951, Sylx = 42.9) for fluoxetine, and y = 0.95x - 1.37 (r = 0.917, Sylx = 47.2) for norfluoxetine.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the antidepressant fluoxetine and its metabolite norfluoxetine in serum by reversed-phase HPLC with ultraviolet detection.

A procedure has been developed for measuring fluoxetine and its desmethyl metabolite, norfluoxetine, in serum by reversed-phase high-performance liquid chromatography (HPLC), with ultraviolet detection at 226 nm. Fluoxetine and norfluoxetine are isolated from serum by liquid-liquid extraction. They are then separated by HPLC and quantified, with reduced haloperidol as the internal standard. Flu...

متن کامل

Serum fluoxetine and norfluoxetine levels support the safety of fluoxetine in overdose

BACKGROUND Previous literature has found fluoxetine to be relatively safe in overdose. This study hopes to examine this idea along with support from published pharmacokinetic information including serum fluoxetine and norfluoxetine levels based on information from a clinical case series. METHODS Four cases are presented along with vital abnormalities, electrocardiogram abnormalities, and phys...

متن کامل

Pharmacokinetics and antidepressant activity of fluoxetine in transgenic mice with elevated serum alpha-1-acid glycoprotein levels.

Fluoxetine, a novel selective serotonin reuptake inhibitor utilized in the treatment of depression, is avidly bound to serum albumin and alpha-1-acid glycoprotein (AAG). AAG is an acute phase protein, and its serum levels are elevated in a variety of pathophysiological conditions including inflammation, depression, cancer, and acquired autoimmune deficiency syndrome. Further, the pharmacokineti...

متن کامل

Sensitive and selective liquid-chromatographic assay of fluoxetine and norfluoxetine in plasma with fluorescence detection after precolumn derivatization.

We determined fluoxetine (Prozac) and its major metabolite norfluoxetine in plasma by liquid chromatography with fluorescence detection. After liquid-liquid extraction from 1 mL of plasma, the extract was derivatized at room temperature with dansyl chloride, and the highly fluorescent derivatives were chromatographed with a reversed-phase C18 column and a mobile phase of phosphate buffer and ac...

متن کامل

Determination of fluoxetine and norfluoxetine in plasma by gas chromatography with electron-capture detection.

This gas-chromatographic method for assay of fluoxetine and norfluoxetine in human plasma involves extraction of the drugs and use of a 63Ni electron-capture detector. The linear range of detection is 25 to 800 micrograms/L for each drug. Overall precision (CV) in the concentration range of 10 to 100 micrograms/L for both drugs was approximately 10%. Accuracy (relative error) in the same concen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 40 7 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1994