The usefulness of using the bispectral index (BIS) for monitoring during cardiopulmonary resuscitation (CPR) is not clearly understood. However, BIS has been a popular anesthetic monitoring device used during operations. The case presented is of a pregnant woman going into cardiac arrest due to an amniotic fluid embolism during a Cesarean section. CPR was performed, but neither the return of spontaneous circulation (ROSC) nor the return of consciousness was achieved, despite 50 min of effective CPR. However, CPR was continued based on BIS. ROSC was achieved, and an alert consciousness state was reached 1 day postoperation. This finding suggests that BIS be used as a basic monitoring device during CPR and that it may help in deciding to continue CPR.
منابع مشابه
Bispectral index monitoring during cardiopulmonary resuscitation repeated twice within 8 days in the same patient: a case report
Research on cardiac resuscitation has led to various changes in the techniques and drug administration involved in modern advanced life support. Besides improving primary cardiac survival, interest is increasingly focused on a favourable neurological outcome. However, until now there has been no on-site equipment to support the clinical observations of the cardiopulmonary resuscitation (CPR) te...
متن کاملValue of bispectral index monitoring during cardiopulmonary resuscitation.
A 67-yr-old man, undergoing pulmonary metastasis resection, experienced a postoperative cardiopulmonary arrest as a result of severe bleeding. Cardiopulmonary resuscitation (CPR) was initiated, then bispectral index (BIS) monitoring was used which reassured the medical team of the adequacy of the resuscitation.
متن کاملWork stress in medical anaesthesiology trainees.
Pract Res Clin Anaesthesiol 2006; 20: 81–99. 3. Kin N, Konstadt SN, Sato K, Hanaoka K. Reduction of bispectral index value associated with clinically significant cerebral air embolism. J Cardiothorac Vasc Anesth 2004; 18: 82–84. 4. Hemmerling TM, Olivier JF, Basile F, Le N, Prieto I. Bispectral index as an indicator of cerebral hypoperfusion during off-pump coronary artery bypass grafting. Anes...
متن کاملPrognostic evaluation of bispectral index in patients following cardiopulmonary resuscitation
The aim of this study was to evaluate the prognosis of patients following cardiopulmonary resuscitation in an intensive care unit (ICU) using bispectral index (BIS) monitoring. The study was a prospective comparative study performed at the academic department of an ICU. A total of 33 adults who received cardiopulmonary resuscitation were enrolled and divided into the surviving and non-surviving...
متن کاملImpact of Bispectral Index Monitoring Versus Clinical Judgment as a Guide for Conduction of Anesthesia on Serum Cortisol Level in Co-ronary Artery Bypass Graft Surgery
Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...