MS Cortical Lesions on DIR: Not Quite What They Seem?

نویسندگان

  • Varun Sethi
  • Nils Muhlert
  • Maria Ron
  • Xavier Golay
  • Claudia A. Wheeler-Kingshott
  • David H. Miller
  • Declan T. Chard
  • Tarek A. Yousry
چکیده

OBJECTIVE Accurate identification and localization of cortical gray matter (CGM) lesions in MS is important when determining their clinical relevance. Double inversion recovery (DIR) scans have been widely used to detect MS CGM lesions. Phase sensitive inversion recovery (PSIR) scans have a higher signal to noise, and can therefore be obtained at a higher resolution within clinically acceptable times. This enables detection of more CGM lesions depicting a clearer cortical and juxtacortical anatomy. In this study, we systematically investigated if the use of high resolution PSIR scans changes the classification of CGM lesions, when compared with standard resolution DIR scans. METHODS 60 patients [30 RR(Relapsing remitting) and 15 each with PP(Primary progressive) and SP(Secondary progressive) MS] were scanned on a 3T Philips Achieva MRI scanner. Images acquired included DIR (1×1×3 mm resolution) and PSIR (0.5×0.5×2 mm). CGM lesions were detected and classified on DIR as intracortical (IC) or leucocortical (LC). We then examined these lesions on corresponding slices of the high resolution PSIR scans and categorized them as IC, LC, Juxtacortical white matter (JC-WM, abutting but not entering cortex) and other white matter (WM, not juxtacortical). Classifications using both scans were noted. RESULTS 282 IC and 483 LC were identified on DIR. Of the IC lesions, 61% were confirmed as IC on PSIR, 35.5% were reclassified as LC and 3.5% as JC-WM or other WM only. Of the LC DIR lesions, 43.9% were confirmed at LC on PSIR, 16.1% were reclassified as IC and 40% as JC-WM or other WM only. Overall, 50% (381/765) of CGM lesions seen on DIR were reclassified, and 26.5% (203/765) affected WM only. CONCLUSIONS When compared with higher resolution PSIR, a significant proportion of lesions classified as involving CGM on DIR appear to either contain more white matter than expected or to not involve CGM at all.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhanced detection of cortical lesions in multiple sclerosis using magnetization transfer and double inversion recovery

Purpose: Multiple sclerosis (MS) has long been considered a pure white matter (WM) disease. In recent years, greater attention is paid to cortical pathology in MS. However, detection of cortical lesions is complicated by low contrast on MRI between lesions and surrounding tissue, the relatively low image resolution, and the confounding signal from WM and cerebrospinal fluid (CSF). Double invers...

متن کامل

The Parallel Analysis of Phase Sensitive Inversion Recovery (PSIR) and Double Inversion Recovery (DIR) Images Significantly Improves the Detection of Cortical Lesions in Multiple Sclerosis (MS) since Clinical Onset

BACKGROUND Double inversion recovery (DIR) detects only a minority (<20%) of cortical lesions (CL) in multiple sclerosis (MS). Phase-sensitive inversion recovery (PSIR) was suggested to be substantially superior to DIR in the detection of cortical lesions (CL). These two sequences might be complementary. OBJECTIVES To analyze CL frequency and type in MS patients having different disease durat...

متن کامل

Postmortem verification of MS cortical lesion detection with 3D DIR.

OBJECTIVE To assess the sensitivity and specificity of 3D double inversion recovery (DIR) MRI for detecting multiple sclerosis (MS) cortical lesions (CLs) using a direct postmortem MRI to histopathology comparison. METHODS Single-slab 3D DIR and 3D fluid-attenuated inversion recovery (FLAIR) images of 56 matched fresh brain samples from 14 patients with chronic MS were acquired at 1.5 T. The ...

متن کامل

Multicontrast MR imaging at 7T in multiple sclerosis: highest lesion detection in cortical gray matter with 3D-FLAIR.

BACKGROUND AND PURPOSE 7T MR imaging has led to improved detection and classification of cortical MS lesions, mainly based on T2*-weighted gradient-echo sequences. Depiction of cortical GM by using the recommended MS imaging protocol has not yet been investigated at 7T. We aimed to investigate prospectively which recommended sequence for clinical use has the highest value at 7T, in terms of GM ...

متن کامل

Reliability of cortical lesion detection on double inversion recovery MRI applying the MAGNIMS-Criteria in multiple sclerosis patients within a 16-months period

PURPOSE In patients with multiple sclerosis (MS), Double Inversion Recovery (DIR) magnetic resonance imaging (MRI) can be used to identify cortical lesions (CL). We sought to evaluate the reliability of CL detection on DIR longitudinally at multiple subsequent time-points applying the MAGNIMs scoring criteria for CLs. METHODS 26 MS patients received a 3T-MRI (Siemens, Skyra) with DIR at 12 ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013