Lifetime Tests for Mac Vertex Chamber*

نویسنده

  • Harry N. Nelson
چکیده

A vertex chamber for MAC was proposed in fall 1983 to increase precision in the measurement of the B hadron and 7 lepton lifetimes. The chamber had to be placed within the existing central drift chamber, making access for repairs difficult and costly. We therefore used for detector elements thin-walled aluminized mylar drift tubes (“straws”) because of their simplicity and robustness. lp2 The diameter of the drift tubes was 6.9 mm. The radial extent of the proposed chamber was from 4.6 cm to 10 cm, the inner wall of the central drift. It was clear that radiation levels, from synchrotron x-rays and overfocussed electrons, were potentially high. Since the drift distance is short in the straws, we wished to operate them at the highest possible gas gain, to achieve the best spatial resolution. There was a likelihood of drawing large currents in the chamber and thus causing radiation damage. We therefore undertook a study of radiation hardness under the conditions of our proposed design. Tests were conducted in the vessel illustrated in Fig. 1. One face of the cubical vessel had a Lucite window, through which we could illuminate the straws within. A list of materials in the chamber appears in Table I. To correspond to final operating conditions, tests were conducted at 4 atma without gas circulation. Table II contains a list of gases used and operating conditions. We have observed that pulses from the 5.9 keV x-rays from Fe55 remain relatively saturated for pressurized, highly quenched Argon-Hydrocarbon mixtures. However, the pulses from single primary electrons, generated by the photoelectric

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Construction of a Vertex Chamber and Measuremement of the Average B-hadron Lifetime*

Four parameters describe the mixing of the three quark generations in the Standard Model of the weak charged current interaction. These four parameters are experimental inputs to the model. A measurement of the mean lifetime of hadrons containing b-quarks, or B-Hadrons, constrains the magnitudes of two of these parameters. Measurement of the B-Hadron lifetime requires a device that can measure ...

متن کامل

Results from the MAC 1 Vertex Chamber * HARRY

The design, construction, and performance characteristics of a high precision gaseous drift chamber made of thin walled proportional tubes are described. The device achieved an average spatial resolution of 45 pm in use for physics analysis with the MAC detector. The B-lifetime result obtained with this chamber is discussed. Invited talk presented at Workshop on Vertex Detectors: State of the A...

متن کامل

Game Theory based Energy Efficient Hybrid MAC Protocol for Lifetime Enhancement of Wireless Sensor Network

Wireless Sensor Networks (WSNs) comprising of tiny, power-constrained nodes are getting very popular due to their potential uses in wide applications like monitoring of environmental conditions, various military and civilian applications. The critical issue in the node is energy consumption since it is operated using battery, therefore its lifetime should be maximized for effective utilization ...

متن کامل

Precise measurement of the lifetime of the tau lepton.

Data accumulated with a high-precision vertex drift chamber operating in the PEP detector MAC are used for a precise measurement of the lifetime of the T lepton. Results from a decay-length analysis of a sample in which one T decays into one charged particle and the other to three charged particles are combined with those from an impact-parameter analysis of an independent sample of events that...

متن کامل

The Time Expansion Chamber as High Precision Drift Chamber

With the principle of the time expansion chamber and the additional measurement of the position of the avalanche along the circumference of the anode wire it is possible to reconstruct the spatial distribution of the primary ionization in space. A position resolution for minimum ionizing tracks of a 5 30 urn is expected. First tests and concepts for vertex detectors are presented.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1986