Transthoracic real-time three-dimensional echocardiography offers additional value in the assessment of mitral valve morphology and area following mitral valve repair.
نویسندگان
چکیده
AIMS The accurate postoperative assessment of mitral valve repair is important not only to document operative outcome, but also to confirm the functional morphology of the repaired valve. METHODS AND RESULTS We assessed 25 consecutive patients following mitral valve repair with transthoracic real-time 3-dimensional echocardiography (RT3DE) and 2-dimensional echocardiography (2DE). We compared the adequacy of the visualization of the mitral valve Carpentier segments, the site of the repair, and the accuracy of planimetry by RT3DE and 2DE in estimating the postoperative mitral valve area (MVA), compared to the Doppler-derived pressure half-time (PHT) value. Inter-observer variability and feasibility were also assessed for RT3DE. Adequate visualization of the mitral valve segments was more frequently obtained by 3DE imaging (163/170 by 3DE vs. 121/170 by 2DE, P < 0.001). In particular, the mitral valve commissures were more clearly identified with 3DE. 3DE also was significantly better at correctly identifying the site of the repaired segment (26/30 by 3DE vs. 19/30 by 2DE, P < 0.05). The difference in MVA (mean difference +/- SD) determined by 3DE planimetry, when compared to PHT was -0.21 +/- 0.46 cm(2) and -0.44 +/- 0.95 cm(2) for 2DE (P = 0.014). Planimetry by 3DE more closely correlated with the MVA calculated by PHT than 2DE planimetry (r = 0.89 for 3DE vs. r = 0.6 for 2DE). Imaging with RT3DE was both feasible, with a mean acquisition time of 4.02 +/- 1.68 min, and data analysis time of 15.82 +/- 3.9 min, and reproducible, with good inter-observer variability for segment scoring with 3DE (kappa = 0.79) and mean inter-observer difference in assessing MVA by 3DE planimetry of 0.18 +/- 0.12 cm(2) (P = NS). CONCLUSION This study suggests that RT3DE offers additional morphological postoperative data of repaired mitral valves, and increases the accuracy of MVA estimation by planimetry. It is both feasible in a busy echocardiography department and reproducible.
منابع مشابه
Real-time three-dimensional transthoracic echocardiography.
BACKGROUND Complex anatomy of intra-cardiac structures requires spatial orientation of image in three dimensions for better understanding and enhanced image interpretation. We evaluated the feasibility and efficacy of the emerging 'real-time three-dimensional transthoracic echocardiography' technique for comprehensive assessment of cardiac anatomy, physiology, pathomorphology and pathophysiolog...
متن کاملReal-time 3-dimensional transesophageal echocardiography in the evaluation of post-operative mitral annuloplasty ring and prosthetic valve dehiscence.
OBJECTIVES This study sought to assess the use of real-time (RT) 3-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) in the evaluation of post-operative mitral valve dehiscence. BACKGROUND Mitral valve replacement or repair may be complicated by post-operative dehiscence of the valve or annuloplasty ring resulting in clinically significant mitral regurgitation or hemol...
متن کاملEffect of position on echocardiographic diagnosis of mitral valve prolapse
Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...
متن کاملRight sided heart evaluation after successful mitral valve replacement.
Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...
متن کاملUtility of real‐time three‐dimensional echocardiography in improved assessment of a mitral valve papillary fibroelastoma
Primary cardiac tumors are exceedingly rare. They are usually first identified by transthoracic echocardiography. However, transesophageal echocardiography (TEE), with the aid of real-time three-dimensional (3D) imaging, can provide additional important mass characteristics. We present a case that demonstrates the usefulness of 3D TEE in characterizing a papillary fibroelastoma.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology
دوره 9 5 شماره
صفحات -