Development of Monolithic Column Materials for the Separation and Analysis of Glycans

نویسنده

  • Allan J. Alla
چکیده

Monolithic column materials offer great advantages as chromatographic media in bioseparations and as solid-supports in biocatalysis. These single-piece porous materials have an interconnected ligament structure that limits the void volume inside the column, thus increasing the efficiency without sacrificing the permeability. The preparation of monolithic materials is easy, reproducible and has available a wide range of chemistries to utilize. Complex, heterogeneous and isobaric glycan structures require preparation methods that may include glycan release, separation and enrichment prior to a comprehensive and site-specific glycosylation analysis. Monolithic column materials aid that demand, as shown by the results reported by the research works presented in this review. These works include selective capture of glycans and glycoproteins via their interactions with lectins, boronic acids, hydrophobic, and hydrophilic/polar functional groups on monolith surfaces. It also includes immobilization of enzymes trypsin and PNGase F on monoliths to digest and deglycosylate glycoproteins and glycopeptides, respectively. The use of monolithic capillary columns for glycan separations through nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC) and coupling these columns to MS instruments to create multidimensional systems show the potential in the development of miniaturized, high-throughput and automated systems of glycan separation and analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Aflatoxin B1 in Iranian Foods Using HPLC and a Monolithic Column and Estimation of its Dietary Intake

A high performance liquid chromatographic method was developed for determination of aflatoxin B1 (AFB1) in foods using a monolithic column with sample clean up on an immunoaffinity column. The method was validated for analysis of AFB1 in rice, bread, puffed corn snack, wheat flour and peanut samples. The average recoveries for AFB1 in different foods ranged from 94.4 to 102.5% with the coeffici...

متن کامل

Analysis of Aflatoxin B1 in Iranian Foods Using HPLC and a Monolithic Column and Estimation of its Dietary Intake

A high performance liquid chromatographic method was developed for determination of aflatoxin B1 (AFB1) in foods using a monolithic column with sample clean up on an immunoaffinity column. The method was validated for analysis of AFB1 in rice, bread, puffed corn snack, wheat flour and peanut samples. The average recoveries for AFB1 in different foods ranged from 94.4 to 102.5% with the coeffici...

متن کامل

Development of a new method based on chiral ligand-exchange chromatography for the enantioseparation of propranolol

A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...

متن کامل

Development of a new method based on chiral ligand-exchange chromatography for the enantioseparation of propranolol

A new chromatographic procedure was proposed for the separation of propranolol (PRN) enantiomers based upon enantioselective chiral ligand-exchange chromatography. The separation was carried out on a short C8 column leading to considerably short separation time. L-alanine and Cu2+ were applied as chiral selector and central bivalent complexing ion, respectively. It was found that the kind of co...

متن کامل

Mass Transfer Coefficients in Pulsed Column for Separation of Samarium and Gadolinium

The mass transfer performance of a pulsed disc and doughnut column for extraction of samarium and gadolinium from aqueous nitrate solution with D2EHPA was investigated. The effects of operating parameters such as pulsation intensity, continuous and dispersed phase velocities on column performance were investigated. The axial dispersion model was used to obtain the overall mass transfer coef...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015