Six- and twelve-month results from first human experience using everolimus-eluting stents with bioabsorbable polymer.
نویسندگان
چکیده
BACKGROUND Everolimus, an active immunosuppressive and antiproliferative agent of the same family as sirolimus (rapamycin), has demonstrated significant reduction of neointimal proliferation in animal studies. The First Use To Underscore restenosis Reduction with Everolimus (FUTURE) I trial was the first in-human experience to evaluate the safety and efficacy of everolimus-eluting stents (EES), coated with a bioabsorbable polymer, compared with bare metal stents (BMS). METHODS AND RESULTS FUTURE I was a prospective, single-blind, randomized trial that enrolled 42 patients with de novo coronary lesions (EES 27, BMS 15). Patient and lesion characteristics were comparable between the groups. Major adverse cardiac event rates were low at 30 days and 6 months, without any early or late stent thrombosis for either group (P=NS). Between 6 and 12 months, there were no additional reports of major adverse cardiac events. The 6-month angiographic in-stent restenosis rate was 0% versus 9.1% (1 patient) (P=NS), with an associated late loss of 0.11 mm versus 0.85 mm (P<0.001), and the in-segment restenosis rate was 4% (1 patient) and 9.1% (1 patient) (P=NS) for EES and BMS, respectively. Intravascular ultrasound analysis revealed a significant reduction of percent neointimal volume in EES compared with BMS (2.9+/-1.9 mm3/mm versus 22.4+/-9.4 mm3/mm, P<0.001). There was no late stent malapposition in either group. The safety and efficacy of the EES appeared to be sustained at 12 months. CONCLUSIONS In this initial clinical experience, EES with bioabsorbable polymer demonstrated a safe and efficacious method to reduce in-stent neointimal hyperplasia and restenosis.
منابع مشابه
Thrombogenicity and early vascular healing response in metallic biodegradable polymer-based and fully bioabsorbable drug-eluting stents.
BACKGROUND Acute thrombogenicity and re-endothelialization represent clinically relevant end points pertaining to the safety of coronary stents, which have not been compared among biodegradable polymer-based drug-eluting metallic stents and fully bioabsorbable scaffolds to date. METHODS AND RESULTS We investigated comparative outcomes with respect to acute thrombogenicity and re-endothelializ...
متن کاملEfficacy and safety of a novel bioabsorbable polymer-coated, everolimus-eluting coronary stent: the EVOLVE II Randomized Trial.
BACKGROUND Drug eluting stents with durable polymers may be associated with hypersensitivity, delayed healing, and incomplete endothelialization, which may contribute to late/very late stent thrombosis and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. The SYNERGY stent is a thin-strut, platinum chromium met...
متن کاملClinical outcomes with bioabsorbable polymer- versus durable polymer-based drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis.
OBJECTIVES This study sought to investigate the relative safety and efficacy of bioabsorbable polymer (BP)-based biolimus-eluting stents (BES) versus durable-polymer (DP)-drug-eluting stents (DES) and bare-metal stents (BMS) by means of a network meta-analysis. BACKGROUND Studies have suggested that BP-BES might reduce the risk of stent thrombosis (ST) and late adverse outcomes compared with ...
متن کاملBare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis
OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...
متن کاملBaremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS
Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 109 18 شماره
صفحات -
تاریخ انتشار 2004