Measurement error as a source of QT dispersion: a computerised analysis.
نویسندگان
چکیده
OBJECTIVE To establish a general method to estimate the measuring error in QT dispersion (QTD) determination, and to assess this error using a computer program for automated measurement of QTD. SUBJECTS Measurements were done on 1220 standard simultaneous 12 lead electrocardiograms. DESIGN The computer program was validated against two observers on a random subset of 100 electrocardiograms. Simple laws of physics require that at least five of the six extremity leads have the same QT duration. This allows the direct assessment of the error in measuring QTD derived from five extremity leads (QTD5). It also enables ST-T amplitude dependent distributions of measurement error in determining QT duration to be established. These QT error distributions were then used to estimate the error in measuring QTD from all 12 leads (QTD12). MAIN OUTCOME MEASURES Mean and standard deviation of error in measuring QTD duration, QTD5, and QTD12. RESULTS Performance of the program was comparable to that of observers. Errors in measuring QT duration (measured QT minus reference QT) fell from a mean (SD) of 6.9 (17.1) ms for ST-T amplitudes < 50 microV to -1.4 (6.3) ms for amplitudes > 350 microV. Measurement errors of QTD5 and QTD12 were 20.4 (11.5) ms and 29.4 (14.9) ms. CONCLUSIONS The fact that no QTD can exist between five of the six extremity leads provides a means of estimating QTD measurement error. Measuring error of QT duration is dependent on ST-T amplitude. QTD measurement error is large compared with typical QTD values reported.
منابع مشابه
Measurement, interpretation and clinical potential of QT dispersion.
QT dispersion was originally proposed to measure spatial dispersion of ventricular recovery times. Later, it was shown that QT dispersion does not directly reflect the dispersion of recovery times and that it results mainly from variations in the T loop morphology and the error of QT measurement. The reliability of both automatic and manual measurement of QT dispersion is low and significantly ...
متن کاملComputerised measurements of QT dispersion in healthy subjects.
OBJECTIVE To assess the stability and reproducibility of computerised QT dispersion (QTd) measurement in healthy subjects, as this is presently being incorporated into commercial electrocardiographic systems. METHODS 70 healthy volunteers (mean (SD) age 38 (10) years, 35 men, 35 women) with a normal 12 lead electrocardiogram (ECG) were studied. From each subject, 70 ECG recordings were taken ...
متن کاملEffect of coronary artery bypass on QT dispersion
Introduction: QT dispersion (QT Max – QT min) reflects inhomogeneous ventricular depolarization that may provide a substrate for serious arrythmias and is associated with adverse clinical outcomes in patients with coronary artery disease. Some studies have shown reduction in QT dispersion after successful angioplasty due to coronary reperfusion, but effect of coronary artery bypass grafting o...
متن کاملQT-Dispersion as a potential marker in prognosis of acute myocardial infarction
Introduction: QT dispersion in a 12 lead ECG represents the heterogeneity of ventricular repolarization. The prolongation of QT-interval dispersion increases the risk of coronary heart disease, ventricular arrhythmia, and sudden cardiac death in patients with myocardial infarction. We aimed to investigate the prognostic value of QT-dispersion in patients with acute myocardial infarction. Meth...
متن کاملReproducibility and automatic measurement of QT dispersion.
This study investigated interobserver (two observers) and intrasubject (two measurements) reproducibility of QT dispersion from abnormal electrocardiograms in patients with previous myocardial infarction, and compared a user-interactive with an automatic measurement system. Standard 12-lead electrocardiograms, recorded at 25 mm.s-1, were randomly chosen from 70 patients following myocardial inf...