Feasibility of aerosol drug delivery to sleeping infants: a prospective observational study
نویسندگان
چکیده
OBJECTIVES Delivery of inhaled medications to infants is usually very demanding and is often associated with crying and mask rejection. It has been suggested that aerosol administration during sleep may be an attractive alternative. Previous studies in sleeping children were disappointing as most of the children awoke and rejected the treatment. The SootherMask (SM) is a new, gentle and innovative approach for delivering inhaled medication to infants and toddlers. The present pilot study describes the feasibility of administering inhaled medications during sleep using the SM. DESIGN Prospective observational study. SETTING Out patients. PARTICIPANTS 13 sleeping infants with recurrent wheezing who regularly used pacifiers and were <12 months old. INTERVENTION Participants inhaled technetium99mDTPA-labelled normal saline aerosol delivered via a Respimat Soft Mist Inhaler (SMI) (Boehringer-Ingelheim, Germany) and SM + InspiraChamber (IC; InspiRx Inc, New Jersey, USA). OUTCOMES The two major outcomes were the acceptability of the treatment and the lung deposition (per cent of emitted dose). RESULTS All infants who fulfilled the inclusion criteria successfully received the SM treatment during sleep without difficulty. Mean lung deposition (±SD) averaged 1.6±0.5% in the right lung. CONCLUSIONS This study demonstrated that the combination of Respimat, IC and SM was able to administer aerosol therapy to all the sleeping infants who were regular pacifier users with good lung deposition. Administration of aerosols during sleep is advantageous since all the sleeping children accepted the mask and ensuing aerosol therapy under these conditions, in contrast to previous studies in which there was frequent mask rejection using currently available devices. CLINICAL TRIAL REGISTRY NCT01120938.
منابع مشابه
Enoxaparin Utilization Evaluation: An Observational Prospective Study in Medical Inpatients
Drug utilization evaluation (DUE) is an effective program to identify variability in drug use and to support interventions that will improve patient outcomes. The appropriate use of enoxaparin, a low molecular weight heparin (LMWH), which is widely used as curative or preventive treatment of thromboembolic disorders was assessed in the study. A prospective DUE was carried out at Masih Daneshvar...
متن کاملEnoxaparin Utilization Evaluation: An Observational Prospective Study in Medical Inpatients
Drug utilization evaluation (DUE) is an effective program to identify variability in drug use and to support interventions that will improve patient outcomes. The appropriate use of enoxaparin, a low molecular weight heparin (LMWH), which is widely used as curative or preventive treatment of thromboembolic disorders was assessed in the study. A prospective DUE was carried out at Masih Daneshvar...
متن کاملAn Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital
Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...
متن کاملAn Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital
Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...
متن کاملAerosol delivery to ventilated infant and pediatric patients.
Infants have low tidal volume, vital capacity, and functional residual capacity, and short respiratory cycles (low I:E ratio), which result in a low residence time for aerosol particles and, thus, low pulmonary deposition of aerosol particles (< 1% of the nominal dose), compared to adults (8-22%). Scintigraphy data suggest aerosol deposition of < 1% in both intubated and nonintubated infants. I...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2014