Validation of walkway tribometers: establishing a reference standard.

نویسندگان

  • Christopher M Powers
  • Mark G Blanchette
  • John R Brault
  • Jim Flynn
  • Gunter P Siegmund
چکیده

Tribometers are mechanical devices used to measure walkway coefficient of friction (COF) for the purpose of assessing slip risk. The purpose of this study was to define a tribometer reference standard and use it to assess the performance of various tribometers. Eighty subjects were randomly assigned to walk across one of four wet walkway surfaces (polished black granite, porcelain, vinyl composition tile, and ceramic tile) to establish the relative slipperiness of each surface. Eleven tribometers were subsequently used to measure and rank the COF of all four surfaces. Our results revealed that only four of the 11 tribometers (Wessex pendulum, Sigler pendulum, Mark II, and Mark III) met our compliance criteria by both correctly ranking all four surfaces and differentiating between surfaces of varying degrees of slipperiness. Our protocol demonstrates that human gait-based measures of slipperiness can be used to create reference standards against which tribometer measurements can be validated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The development of a universal approach to testing of walkway slip resistance in the U.S.

The measurement of walkway slip resistance is required to assess the risk of slipping. Unlike other countries, the U.S. has not decided upon a single approach to the measurement of slip resistance. Several types of tribometers are available to measure slip resistance however, the measured value of the slip resistance of a given surface has been found to be tribometer specific. The introduction ...

متن کامل

Some steps towards establishing a tertiary standard dosimetry laboratory at a radiotherapy department

Background: In order to deliver the precise dose to the target in radiotherapy, absorbed dose to water at the reference point should be assessed. When the calibration procedure is performed for a reference dosimeter in the 60Co beam of a Secondary Standard Dosimetry Laboratory (SSDL), the total uncertainty in absorbed dose to water (Dw) is estimated to be approximately 1.5%. This study attempts...

متن کامل

Protocol Variations and Six-Minute Walk Test Performance in Stroke Survivors: A Systematic Review with Meta-Analysis

Objective. To investigate the use of the six-minute walk test (6MWT) for stroke survivors, including adherence to 6MWT protocol guidelines and distances achieved. Methods. A systematic search was conducted from inception to March 2014. Included studies reported a baseline (intervention studies) or first instance (observational studies) measure for the 6MWT performed by stroke survivors regardle...

متن کامل

Assessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels

Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...

متن کامل

Validation of Volunteered Geographic Information Landuse Change Using Satellite Imagery

Land use change monitoring is one of the main concerns of managers and urban planners due to human activities and unbalanced physical development in urban areas. In this paper, a combination of remote sensing data and volunteered geographic information was used to assess the quality of volunteered geographic information on land use and land cover changes monitoring. For this purpose, the ORBVIE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of forensic sciences

دوره 55 2  شماره 

صفحات  -

تاریخ انتشار 2010