Can Fatigue Strength of Locking Plates be Improved by Plugging the Unfilled Screw Holes in Comminuted Supracondylar Femur Fractures

ثبت نشده
چکیده

Figure 4 –Typical failures of the plugged (left), screw only (center) and unplugged (right) comparison groups. Can Fatigue Strength of Locking Plates be Improved by Plugging the Unfilled Screw Holes in Comminuted Supracondylar Femur Fractures McDonald, E; Firoozabadi, R; Nguyen, TQ; Buckley, J.M; +Kandemir, U +Biomechanical Testing Facility, UCSF/SFGH Orthopaedic Trauma, University of California at San Francisco, San Francisco, CA, USA Department of Orthopaedic Surgery, University of California at San Francisco, San Francisco, CA, USA [email protected]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Immediate weight bearing of comminuted supracondylar femur fractures using locked plate fixation.

Comminuted supracondylar femur fractures (AO-OTA 33A3) are commonly treated with locked plates. Weight bearing is generally restricted for 6 to 12 weeks until radiologic evidence exists of sufficient callous to support weight bearing. Recent clinical studies have reported high nonunion rates with distal femur locked plates. In an attempt to induce beneficial motion across the fracture site, som...

متن کامل

Polyaxial locking plate fixation in distal femur fractures: a biomechanical comparison.

OBJECTIVES Uniaxial, first-generation locking plates have become increasingly popular for fixation of supracondylar femur fractures. Polyaxial plates are currently available, which allow for variable-angle screw insertion; however, the biomechanical integrity of these new locking constructs is yet unproven. This study compares the mechanical stability of a conventional locking plate with that o...

متن کامل

Does locked plating of periprosthetic supracondylar femur fractures promote bone healing by callus formation? Two cases with opposite outcomes.

Contemporary locking plates promote biological fixation through indirect reduction techniques and by elevating the plate from the bone. They have improved fixation strength in osteoporotic bone. Periarticular locking plates are rapidly being adopted for bridge plating of periprosthetic femur fractures. When these plates are used for indirect reduction and bridge plating osteosynthesis, fracture...

متن کامل

Intramedullary nails with distal interlocking screws locked to the nail may have higher fatigue strength in comminuted supracon

Figure 2. Specimen mounted on the MTS. Intramedullary nails with distal interlocking screws locked to the nail may have higher fatigue strength in comminuted supracondylar femur fractures McDonald, E;, Fischer, J; Bartlett, T; Buckley, J.M; Pekmezci, M, +Kandemir, U +Biomechanical Testing Facility, UCSF/SFGH Orthopaedic Trauma, University of California at San Francisco, San Francisco, CA, USA D...

متن کامل

An Unusual Case of “Locking” of the Knee Four Years Post Fixation of an Open Supracondylar Femur Fracture

UNLABELLED The introduction of locking plate devices have increased the number of viable options for fracture fixation. An understanding of the indications and contraindications and technique limitations are important to minimise associated adverse events. We report the case of a patient who presented with a single broken screw head four years following fixation of a supracondylar femur fractur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010