New extraction method for radioimmunoassay of serum estradiol.

نویسنده

  • P B Eriksen
چکیده

A new extraction procedure is applied here to radioimmunoassay of serum estradiol. Small columns packed with porous, grainy kieselguhr are loaded with the samples. The kieselguhr material acts as support for the water phase, from which the lipophilic compound estradiol is eluted with diethyl ether. With use of a specially constructed rack, several columns can be handled simultaneously, which makes the procedure convenient for routine use: 40 columns can be processed in about 30 min, including application of samples, elution, and evaporation of solvent. The results correlate well (r = 0.98) with those by conventional liquid-liquid extraction, and the new method has lower interassay coefficients of variation. When tritiated estradiol in water solution was applied onto the columns, 97.7% was recovered in the extract. The current cost of materials used for the extraction is about $0.20 per column.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of steroids in songbird plasma and brain by coupling solid phase extraction to radioimmunoassay.

It is a common practice to extract steroids from plasma, serum, or tissue samples prior to steroid measurement by radioimmunoassay (RIA) or enzyme immunoassay (EIA). Steroid extraction is critical because it can remove substances that interfere with the RIA or EIA. Steroid extraction is commonly achieved using organic solvents, such as diethyl ether or dichloromethane. However, organic solvent ...

متن کامل

Evaluation of a radioimmunoassay for estradiol in unextracted serum.

We describe the performance of a commercial (Steranti/EIR) RIA reagent kit for measuring 17 beta-estradiol directly in serum. Day-to-day precision data for control sera were as follows: mean = 102.8 ng/L, CV = 6.8%, n = 20; mean = 231.1 ng/L, CV = 5.3%, n = 21; mean = 747.7 ng/L, CV = 9.4%, n = 21. Analytical recovery of added estradiol from seven different serum pools from men, to which three ...

متن کامل

A purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17beta-estradiol in prepubertal children.

OBJECTIVE To test the clinical usefulness of sensitive commercial immunoassays for determination of low 17beta-estradiol concentrations in children. METHODS The lower limit of detection and clinical usefulness (functional sensitivity) of three commercial estradiol immunoassays were validated by use of 500 sera from prepubertal and pubertal children and 55 pooled sera. The three immunoassays c...

متن کامل

Facile radioimmunoassay of estradiol 3-sulfate in plasma during pregnancy.

A facile, sensitive radioimmunoassay of estradiol 3-sulfate in pregnancy plasma was established. Highly specific antisera were raised in male rabbits against a conjugate of 6-oxoestradiol 3-sulfate-(O-carboxymethyl)oxime with bovine serum albumin. After purification of the antiserum, we coupled the crude globulin fraction to CNBr-activated Sepharose-4B and used this for direct radioimmunoassay ...

متن کامل

A SPECIFIC, SENSITIVE, AND ONE-STEP EXTRACTION RADIOIMMUNOASSAY OF TESTOSTERONE FOR CLINICAL DIAGNOSIS

Testosterone was measured using antibodies raised against testosterone II B-carboxymethyl ether bovine serum albmin (T-IIB-CME-BSA) and testosterone 3- O-carboxymethyl oxime-BSA as immunogen. The antibody produced in this study exhibits minimal cross reactivity with the structurally related steroids specially 5 dihydrotestosterone (5 DHD. This allows to ommit the clean up step and measure ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 11  شماره 

صفحات  -

تاریخ انتشار 1981