Evaluating image reconstruction methods for tumor detection in 3-dimensional whole-body PET oncology imaging.

نویسندگان

  • Carole Lartizien
  • Paul E Kinahan
  • Richard Swensson
  • Claude Comtat
  • Michael Lin
  • Victor Villemagne
  • Régine Trébossen
چکیده

UNLABELLED We compare 3 image reconstruction algorithms for use in 3-dimensional (3D) whole-body PET oncology imaging. We have previously shown that combining Fourier rebinning (FORE) with 2-dimensional (2D) statistical image reconstruction via the ordered-subsets expectation-maximization (OSEM) and attenuation-weighted OSEM (AWOSEM) algorithms demonstrates improvements in image signal-to-noise ratios compared with the commonly used analytic 3D reprojection (3DRP) or FORE+FBP (2D filtered backprojection) reconstruction methods. To assess the impact of these reconstruction methods on detecting and localizing small lesions, we performed a human observer study comparing the different reconstruction methods. The observer study used the same volumetric visualization software tool that is used in clinical practice, instead of a planar viewing mode as is generally used with the standard receiver operating characteristic (ROC) methodology. This change in the human evaluation strategy disallowed the use of a ROC analysis, so instead we compared the fraction of actual targets found and reported (fraction-found) and also investigated the use of an alternative free-response operating characteristic (AFROC) analysis. METHODS We used a non-Monte Carlo technique to generate 50 statistically accurate realizations of 3D whole-body PET data based on an extended mathematic cardiac torso (MCAT) phantom and with noise levels typical of clinical scans performed on a PET scanner. To each realization, we added 7 randomly located 1-cm-diameter lesions (targets) whose contrasts were varied to sample the range of detectability. These targets were inserted in 3 organs of interest: lungs, liver, and soft tissues. The images were reconstructed with 3 reconstruction strategies (FORE+OSEM, FORE+AWOSEM, and FORE+FBP). Five human observers reported (localized and rated) 7 targets within each volume image. An observer's performance accuracy with each algorithm was measured, as a function of the lesion contrast and organ type, by the fraction of those targets reported and by the area below the AFROC curve. This AFROC curve plots the fraction of reported targets at each rating threshold against the fraction of cases with (> or =1) similarly rated false reports. RESULTS Images reconstructed with FORE+AWOSEM yielded the best overall target detection as compared with FORE+FBP and FORE+OSEM, although these differences in detectability were region specific. The FORE+FBP and FORE+AWOSEM algorithms had similar performances for liver targets. The FORE+OSEM algorithm performed significantly worse at target detection, especially in the liver. We speculate that this is the result of using an incorrect statistical model for OSEM and that the incorporation of attenuation weighting in AWOSEM largely compensates for this model inaccuracy. These results were consistent for both the fraction of actual targets found and the AFROC analysis. CONCLUSION We demonstrated the efficacy of performing observer detection studies using the same visualization tools as those used in clinical PET oncology imaging. These studies demonstrated that the FORE+AWOSEM algorithm led to the best overall detection and localization performance for 1-cm-diameter targets compared with the FORE+OSEM and FORE+FBP algorithms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST

Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...

متن کامل

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

Impact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer

Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...

متن کامل

The influence of using different reconstruction algorithms on sensitivity of quantitative 18F-FDG-PET volumetric measures to background activity variation

Introduction: This study aims to investigate the influence of background activity variation on image quantification in differently reconstructed PET/CT images. Methods: Measurements were performed on a Discovery-690 PET/CT scanner using a custom-built NEMA-like phantom. A background activity level of 5.3 and 2.6 kBq/ml 18F-FDG were applied. Ima...

متن کامل

Easy detection of tumor in oncologic whole-body PET by projection reconstruction images with maximum intensity projection algorithm.

Whole-body PET scanning for an oncology study produces a large number of transaxial images by data acquisition over multiple bed positions. The sagittal and coronal reformatted images are often used for better understanding of radioisotope distribution. We reduced the number of PET images by calculating projection images and evaluated the merit of additional data processing for the visualizatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 44 2  شماره 

صفحات  -

تاریخ انتشار 2003